Cart0items

Cart

Pre-Black Friday Sale : Up to 65% Off | Use code "BLACK"

Offer Expires in

  • 00
  • 00
  • 00
  • 00
0
0
Cart0items

Cart

HomeShopTesting EquipmentFluke 123B Industrial ScopeMeter Hand-Held Oscilloscope, 20 MHz

Description

Fluke 123B OffersCompact and rugged, this oscilloscope is ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. Features innovative functions that help technicians troubleshoot faster for quicker results and to keep their systems running smoothly. Additionally, triggering displays waveforms without having to adjust amplitude, timebase, and trigger settings.

Features

Key measurements: Power waveforms with numerical values including resistance, diode, continuity and capacitance measurements
Automatically capture, view and analyze complex waveforms: Fluke Connect and View™ triggering automatically displays waveforms without having to adjust amplitude, timebase and trigger settings, while Intellaset™ technology analyzes the signal and automatically displays critical numerical readings, making troubleshooting faster than ever
View data locally on the instrument, or via Fluke Connect mobile app
Dual-input digital oscilloscope and multimeter
20 MHz oscilloscope bandwidth
Two 5000-count True RMS digital multimeters
Connect-and-View trigger simplicity for hands-off operation
IntellaSet technology automatically and intelligently adjusts numerical readout based on the measured signal
Dual-input waveform and meter reading recorder for trending data over extended periods
Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
Shielded test leads for oscilloscope, resistance and continuity measurements
Resistance, continuity, diode and capacitance meter measurements
Power measurements (W, VA, VAR, PF, DPF, Hz)
Save or recall data and instrument setups
Store instrument setups defined by a test sequence for routine maintenance or most often used test procedures
External optically isolated USB interface to transfer, archive and analyze scope or meter data
Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect mobile app
Rugged design to withstand 3 g Vibration, 30 g shock, and rated IP51 according to EN/IEC60529
Highest safety rating in the industry: safety rated for CAT IV 600 V

Connect-and-View triggering for an instant, stable display
Oscilloscope users know how difficult triggering can be. Using the wrong settings can lead to unstable waveform captures, and sometimes the wrong measurement data. This instrument’s unique Connect-andView triggering technology recognizes signal patterns and automatically sets up the correct triggering to provide a stable, reliable, and repeatable display. Connect-and-View triggering is designed to work with virtually any signal, including motor drives and control signals – without adjusting parameters, or even touching a button. Signal changes are instantly recognized and settings are automatically adjusted, providing a stable display even when measuring multiple test points in quick succession.

IntellaSet/AutoReading
The Auto Readings function with Fluke IntellaSet technology uses proprietary algorithms to intelligently analyze the measured waveform and automatically displays the most appropriate numerical measurements on the screen, so you can get the data you need easier than ever before. As an example, when the measured waveform is a line voltage signal, the Vrms and Hz readings are automatically displayed, whereas if the measured waveform is a square wave, the Vpeak-peak, and Hz readings are automatically displayed. Using IntellaSet technology in conjunction with Connect-and-View automatic triggering you can be sure you’re seeing not only the correct waveform but the appropriate numerical reading as well. All without touching a button.

Industrial equipment needs a reliable power supply to operate properly, use the dual input to obtain key power measurements
For single-phase or 3-phase balanced systems, the dual inputs of this industrial ScopeMeter can measure AC+DC RMS voltage on channel A and AC+DC RMS current on channel B.

One test lead to measure multiple electrical parameters

High-frequency waveform, meter, capacitance, and resistance measurements as well as continuity checks are all covered by a single set of shielded test leads. No time is wasted finding or swapping leads.

Fluke Connect mobile app compatibility
Automated industrial machinery is harder than ever to troubleshoot. It’s not enough to just know where you have to test, you also have to know what to look for and that can be hard without baseline measurement data or access to subject matter experts. This Fluke Connect Assets wireless system of software and wireless test tools enables technicians to reduce maintenance costs and increase uptime with accurate equipment records and maintenance data that is easy to interpret, and share. Compare and contrast test point measurement data and trends so you can better understand signal characteristics and changes over time. And, by storing maintenance data on the Fluke Cloud you can enable team members to access it from wherever and whenever they need to so you can get advice or approvals in the field and get your systems up and running faster than ever before.

Use the comprehensive recorder modes to help find intermittent faults with ease
The toughest faults to find are those that happen only once in a while-intermittent event. They can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Other factors, like line outages and sags or the starting and stopping of a motor, can also cause intermittent events resulting in equipment shutdowns. When these events happen, you may not be around to see them. But, your ScopeMeter test tool will. You can either plot the minimum and maximum peak measurement values or record the waveform trace. And, with expandable micro SD memory, recording sessions can be done for up to 14 days. This recorder is even more powerful with the addition of Recorder Event Detect, which makes detecting and logging intermittent faults easier than ever. Just set a threshold on a meter reading or scope trace and deviations are tagged as unique events. You no longer need to search through masses of data to pinpoint faults, and can quickly step from one tagged event to the next, while still having access to the full data set.

Applications
Ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications.Fluke 123B OffersCompact and rugged, this oscilloscope is ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications. Features innovative functions that help technicians troubleshoot faster for quicker results and to keep their systems running smoothly. Additionally, triggering displays waveforms without having to adjust amplitude, timebase, and trigger settings.

Features

Key measurements: Power waveforms with numerical values including resistance, diode, continuity and capacitance measurements
Automatically capture, view and analyze complex waveforms: Fluke Connect and View™ triggering automatically displays waveforms without having to adjust amplitude, timebase and trigger settings, while Intellaset™ technology analyzes the signal and automatically displays critical numerical readings, making troubleshooting faster than ever
View data locally on the instrument, or via Fluke Connect mobile app
Dual-input digital oscilloscope and multimeter
20 MHz oscilloscope bandwidth
Two 5000-count True RMS digital multimeters
Connect-and-View trigger simplicity for hands-off operation
IntellaSet technology automatically and intelligently adjusts numerical readout based on the measured signal
Dual-input waveform and meter reading recorder for trending data over extended periods
Recorder Event Detect captures elusive intermittent signals on repetitive waveforms up to 4 kHz
Shielded test leads for oscilloscope, resistance and continuity measurements
Resistance, continuity, diode and capacitance meter measurements
Power measurements (W, VA, VAR, PF, DPF, Hz)
Save or recall data and instrument setups
Store instrument setups defined by a test sequence for routine maintenance or most often used test procedures
External optically isolated USB interface to transfer, archive and analyze scope or meter data
Optional WiFi adapter connected to internal USB port to wirelessly transfer information to the PC, laptop or Fluke Connect mobile app
Rugged design to withstand 3 g Vibration, 30 g shock, and rated IP51 according to EN/IEC60529
Highest safety rating in the industry: safety rated for CAT IV 600 V

Connect-and-View triggering for an instant, stable display
Oscilloscope users know how difficult triggering can be. Using the wrong settings can lead to unstable waveform captures, and sometimes the wrong measurement data. This instrument’s unique Connect-andView triggering technology recognizes signal patterns and automatically sets up the correct triggering to provide a stable, reliable, and repeatable display. Connect-and-View triggering is designed to work with virtually any signal, including motor drives and control signals – without adjusting parameters, or even touching a button. Signal changes are instantly recognized and settings are automatically adjusted, providing a stable display even when measuring multiple test points in quick succession.

IntellaSet/AutoReading
The Auto Readings function with Fluke IntellaSet technology uses proprietary algorithms to intelligently analyze the measured waveform and automatically displays the most appropriate numerical measurements on the screen, so you can get the data you need easier than ever before. As an example, when the measured waveform is a line voltage signal, the Vrms and Hz readings are automatically displayed, whereas if the measured waveform is a square wave, the Vpeak-peak, and Hz readings are automatically displayed. Using IntellaSet technology in conjunction with Connect-and-View automatic triggering you can be sure you’re seeing not only the correct waveform but the appropriate numerical reading as well. All without touching a button.

Industrial equipment needs a reliable power supply to operate properly, use the dual input to obtain key power measurements
For single-phase or 3-phase balanced systems, the dual inputs of this industrial ScopeMeter can measure AC+DC RMS voltage on channel A and AC+DC RMS current on channel B.

One test lead to measure multiple electrical parameters

High-frequency waveform, meter, capacitance, and resistance measurements as well as continuity checks are all covered by a single set of shielded test leads. No time is wasted finding or swapping leads.

Fluke Connect mobile app compatibility
Automated industrial machinery is harder than ever to troubleshoot. It’s not enough to just know where you have to test, you also have to know what to look for and that can be hard without baseline measurement data or access to subject matter experts. This Fluke Connect Assets wireless system of software and wireless test tools enables technicians to reduce maintenance costs and increase uptime with accurate equipment records and maintenance data that is easy to interpret, and share. Compare and contrast test point measurement data and trends so you can better understand signal characteristics and changes over time. And, by storing maintenance data on the Fluke Cloud you can enable team members to access it from wherever and whenever they need to so you can get advice or approvals in the field and get your systems up and running faster than ever before.

Use the comprehensive recorder modes to help find intermittent faults with ease
The toughest faults to find are those that happen only once in a while-intermittent event. They can be caused by bad connections, dust, dirt, corrosion, or simply broken wiring or connectors. Other factors, like line outages and sags or the starting and stopping of a motor, can also cause intermittent events resulting in equipment shutdowns. When these events happen, you may not be around to see them. But, your ScopeMeter test tool will. You can either plot the minimum and maximum peak measurement values or record the waveform trace. And, with expandable micro SD memory, recording sessions can be done for up to 14 days. This recorder is even more powerful with the addition of Recorder Event Detect, which makes detecting and logging intermittent faults easier than ever. Just set a threshold on a meter reading or scope trace and deviations are tagged as unique events. You no longer need to search through masses of data to pinpoint faults, and can quickly step from one tagged event to the next, while still having access to the full data set.

Applications
Ideal for industrial electrical and electro-mechanical equipment troubleshooting and maintenance applications.

Fluke 123B Specifications

Oscilloscope Mode (Vertical)

Frequency Response – DC Coupled
Without probes and test leads (with BB120): DC to 20 MHz (-3 dB)

With STL120-IV 1:1 shielded test leads: DC to 12.5 MHz (-3 dB), DC to 20 MHz (-6 dB)

With VP41 10:1 probe: DC to 20 MHz (-3 dB)

Frequency Response – AC Coupled (LF Roll Off)
Without probes and test leads: <10 Hz (-3 dB) With STL120-IV 1:1 shielded test leads: <10 Hz (-3 dB) With VP41 10:1 probe: <10 Hz (-3 dB) Rise Time, Excluding Probes, Test Leads <17.5 ns Input Impedance Without probes and test leads: 1 MΩ/20 pF With BB120: 1 MΩ/24 pF With STL120-IV 1:1 shielded test leads: 1 MΩ/230 pF With VP41 10:1 probe: 5 MΩ/15.5 pF Sensitivity 5 mV to 200 V/div Analog Bandwidth Limiter 10 kHz Display Modes A, -A, B, -B Maximum Input Voltage A and B Direct, with test leads, or with VP41 probe: 600 Vrms CAT IV, 750 Vrms maximum voltage With BB120: 600 Vrms Maximum Floating Voltage, from any Terminal to Ground 600 Vrms CAT IV, 750 Vrms up to 400 Hz Oscilloscope Mode (Horizontal) Scope Modes Normal, single, roll Ranges (Normal) Equivalent sampling: 20 ns to 500 ns/div Real time sampling: 1 μs to 5 s/div Single (real time): 1 μs to 5 s/div Roll (real time): 1 s to 60 s/div Sampling Rate (for Both Channels Simultaneously) Equivalent sampling (repetitive signals): up to 4 GS/s Real time sampling 1 μs to 60 s/div: 40 MS/s Trigger Screen Update Free run, on trigger Source A, B Sensitivity A and B At DC to 5 MHz: 0.5 divisions or 5 mV At 40 MHz: 4 divisions Slope Positive, negative Advanced Scope Functions Display Modes Normal: Captures up to 25 ns glitches and displays analog-like persistence waveform Smooth: Suppresses noise from a waveform Glitch off: Does not capture glitches between samples Envelope: Records and displays the minimum and maximum of waveforms over time Auto Set (Connect-and-View) Continuous fully automatic adjustments of amplitude, time base, trigger levels, trigger gap, and hold-off. Manual override by user adjustment of amplitude, time base, or trigger level Input A and B DC Voltage (V DC) Ranges: 500 mV, 5, 50, 500, 750 V Accuracy: ±(0.5% +5 counts) Common mode rejection (CMRR): >100 dB at DC, >60 dB at 50, 60, or 400 Hz

Full scale reading: 5000 counts

True RMS Voltages (V AC and V AC+DC)
Ranges: 500 mV, 5, 50, 500, 750 V

Accuracy for 5 to 100% of range (DC coupled)

DC to 60 Hz (V AC + DC): ±(1% +10 counts)

1 to 60 Hz (V AC): ±(1% +10 counts)

Accuracy for 5 to 100% of range (AC or DC coupled): 60 Hz to 20 kHz: ±(2.5% +15 counts)

DC rejection (only V AC): >50 dB

Common mode rejection (CMRR): >100 dB at DC; >60 dB at 50, 60, or 400 Hz

Full scale reading: 5000 counts, reading is independent of any signal crest factor

Peak
Modes: Maximum peak, minimum peak, peak-to-peak

Ranges: 500 mV, 5, 50, 500, 2200 V

Accuracy: Maximum peak or minimum peak: 5% of full scale; peak-to-peak: 10% of full scale

Full scale reading: 500 counts

Frequency
Ranges: 1, 10, 100 Hz, 1, 10, 100 kHz, 1, 10, and 50 MHz

Frequency range: 15 Hz (1 Hz) to 50 MHz in continuous autoset

Accuracy at 1 Hz to 1 MHz: ±(0.5% +2 counts)

Full scale reading: 10,000 counts

RPM
Maximum reading: 50 kRPM

Accuracy: ±(0.5% +2 counts)

Duty Cycle
Range: 2 to 98%

Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset

Pulse Width
Frequency range: 15 Hz (1 Hz) to 30 MHz in continuous autoset

Full scale reading: 1000 counts

Amperes
With current clamp

Ranges: same as V DC, V AC, V AC+DC, or peak

Scale factors: 0.1, 1, 10, 100, 400 mV/A, 1 V/A, 10 mV/mA

Accuracy: same as V DC, V AC, V AC+DC, or peak (add current clamp uncertainty)

Decibel
0 dBV: 1 V

0 dBm (600/50 Ω): 1 mW referenced to 600 or 50 Ω

dB on V DC, V AC, or V AC+DC

Full scale reading; 1000 counts

Crest Factor
Range: 1 to 10

Full scale reading: 90 counts

Phase
Modes: A to B, B to A

Range: 0 to 359°

Resolution: 1°

Vpwm
Purpose: To measure on pulse width modulated signals, like motor drive inverter outputs

Principle: Readings show the effective voltage based on the average value of samples over a whole number of periods of the fundamental frequency

Accuracy: As Vrms for sine wave signals

Input A to Common

Ohm
Ranges: 500 Ω, 5, 50, 500 kΩ, 5, 30 MΩ

Accuracy: ±(0.6% +5 counts) 50 Ω ±(2% +20 counts)

Full scale reading: 50 Ω to 5 MΩ – 5000 counts; 30 MΩ – 3000 counts

Measurement current: 0.5 mA to 50 nA, decreases with increasing ranges

Open circuit voltage: <4 V Common Continuity (Cont) Beep: <(30 Ω ±5 Ω) in 50 Ω range Measurement current: 0.5 mA Detection of shorts of: ≥1 ms Common Diode Measurement voltage: At 0.5 mA: >2.8 V

At open circuit: <4 V Measurement current: 0.5 mA Polarity: + on input A, - on COM Capacitance (CAP) Ranges: 50, 500 nF, 5, 50, 500 μF Full scale reading: 5000 counts Measurement current: 500 nA to 0.5 mA, increases with increasing ranges Advanced Meter Functions Zero Set Set actual value to reference AutoHold (on A) Captures and freezes a stable measurement result. Beeps when stable. AutoHold works on the main meter reading, with thresholds of 1 Vpp for AC signals and 100 mV for DC signals Fixed Decimal Point Activated by using attenuation keys Recorder Meter Readings Measurement speed: Maximum 2 measurements Record size (minimum, maximum, average): 2 M readings for 1 channel Recorded time span: 2 weeks Maximum number of events: 1024 Waveform Record Maximum sample rate: 400 K samples Size internal memory: 400 M samples recorded time Span internal memory: 15 minutes at 500 μs/div; 11 hours at 20 ms/div Record size SD card: 1.5 G samples Recorded time span SD card: 11 hours at 500 μs/div; 14 days at 20 ms/div Maximum number of events: 64 General Specifications Waveform Display Vertical: 10 div of 40 pixels Horizontal: 12 div of 40 pixels Maximum Input Voltage A and B Direct on input or with leads: 600 Vrms CAT IV for derating With banana-to BNC adapter BB120: 600 Vrms for derating Maximum floating voltage from any terminal to ground: 600 Vrms CAT IV, 750 Vrms up to 400 Hz Display Type: 5.7" color active martrix TFT Resolution: 640 x 480 Interface Optically isolated: Transfer screen copies (bitmaps), settings and data USB to PC/laptop: OC4USB optically isolated USB adapter/cable, (optional), using FlukeView® software for Windows® Wireless Radio with Adapter Frequency range: 2412 to 2462 MHz Output power: <100 mW Environmental MIL-PRF-28800F, Class 2 Temperature Battery operation: 32 to 104°F (0 to 40°C) Power adapter operation: 32 to 122°F (0 to 50°C) Storage: -4 to 140°F (-20 to 60°C) non-condensing Humidity (Operating) At 32 to 50°F (0 to 10°C): non-condensing At 50 to 86°F (10 to 30°C): 95% At 86 to 104°F (30 to 40°C): 75% At 104 to 122°F (40 to 50°C): 45% Altitude Operating at 10,000' (3 km): CAT III 600 V Operating at 6600' (2 km): CAT IV 600 V Storage: 40,000' (12 km) EMC Electromagnetic Compatibility USA (FCC): 47 CFR 15 subpart B (this product is considered an exempt device per clause 15.103) Enclosure Protection IP51, ref: EN/IEC60529 Safety General: IEC 61010-1: Pollution Degree 2 Measurement: IEC 61010-2-033: CAT IV 600 V/CAT III 750 V Memory Internal memory can store 20 data sets (screen waveform and setup) Micro SD card slot with optional SD card (maximum size of 32 GB) Power External: Via power adapter BC430 Input voltage: 10 to 21 V DC Consumption: 5 W typical Input connector: 5 mm jack Internal: Via battery pack BP290 Battery power: Rechargeable Li-Ion 10.8 V Operating time: 7 hours with 50 % backlight brightness Charging time: 4 hours with test tool off, 7 hours with test tool on Allowable ambient temperature: 32 to 104°F (0 to 40°C) during charging Dimensions 10.2 x 5.2 x 2.15" (259 x 132 x 55 mm) Weight 3.2 lbs (1.4 kg) including battery pack Click here for complete specifications on the Fluke 123B What's included with the Fluke 123B Oscilloscope 2 x Shielded Test Leads with Ground Leads Black Test Lead Red and Blue Hook Clips Banana to BNC Adapter Wi-Fi USB Adapter Li-Ion Battery Pack Charger/Power Adapter See it. Save it. Share it. All the facts, right in the field. Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry. Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world. Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity. Fluke Connect Features: TrendIt™ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly. EquipmentLog™ History: Access equipment history building a database of equipment health and baselines with cloud backup. ShareLive™ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere. AutoRecord™ Measurements: Instantly save measurements to your phone with Cloud backup. Fluke Cloud™ Storage: Securely access equipment records anywhere, anytime. Fluke Connect Benefits: Maximize uptime Minimize maintenance costs Better assessments with accurate records Higher efficiency with less walking around; no notebook and excel needed Share troubleshooting knowledge live Create and share helpful content in the field Access to Fluke digital product manuals means no need to carry manuals in the field Keep organized manually entered measurements Webinar: EVSE Safety Maintenance with Fluke In recent years, more people are opting for greener solutions to minimize environmental damage, which has led to an increased demand for environmentally safe solutions such as electric vehicles. Naturally, this has led to an increase in the installation of EV charging stations, but also the risks for technicians. In 2020, there were 126 fatal and 2200 non-fatal electrical injuries. Many of these are caused when technicians are exposed to hazardous voltage and arc faults that could cause shock and fire hazards due to a lack of understanding of proper EVSE installation and maintenance. Considering that EVSEs have a high rate of failure, estimated at 30 to 50% (SAE), reliability is essential when building EV infrastructure and gaining user acceptance.

Reviews

There are no reviews yet.

Be the first to review “Fluke 123B Industrial ScopeMeter Hand-Held Oscilloscope, 20 MHz”

Your email address will not be published. Required fields are marked *

Select your currency