Cells Per Unit 6
Voltage Per Unit 12 V
Capacity 17 Ah @ 20hr-rate to 1.75V per cell @ 25°C (77°F)
Weight (kg) Approx. 5.5 kg. (12.12 lbs.)
Maximum Discharge current (A) 230 A (5sec.)
Internal Resistance Approx. Approx. 14.0 mΩ
Operating Temperature Range Discharge:-15℃~50℃(5°F~122°F)
Charge:-15℃~40℃(5°F~104°F)
Storage:-15℃~40℃(5°F~104°F)
Nominal Operating Temperature Range 25°C ± 3°C (77°F ± 5°F)
Float charging voltage 13.5 to 13.8 VDC/unit Average at 25°C (77°F)
Recommended Maximum Charging current limit 5.1A
Equalization and Cycle Service 14.4 to 15.0 VDC/unit Average at 25°C (77°F)
Self Discharge It should be more than 75% of the capacity that before storage after stocked for 6 months at ambient temp. 25℃
Terminal B1/B3-L terminal to accept M5 nut & bolt
Container Material ABS(UL94-HB) & Flammability resistance of(UL94-V0) can be available upon request.