Description
Designed by electricians. Engineered by Fluke.
Compact true-rms meter for electrical troubleshooting. The Fluke 114 is a battery-powered, true-rms multimeter the perfect troubleshooting tool for “go/no-go” testing. It includes a feature to prevent false readings caused by ghost voltage.
Also check out the Fluke 115 Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.
What’s Included:
HolsterInstalled 9 V batteryTest leadsUser manualDesigned by electricians. Engineered by Fluke.
Compact true-rms meter for electrical troubleshooting. The Fluke 114 is a battery-powered, true-rms multimeter the perfect troubleshooting tool for “go/no-go” testing. It includes a feature to prevent false readings caused by ghost voltage.
Also check out the Fluke 115 Multimeter, the Fluke 116 HVAC Multimeter with Temperature and Microamps, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.
What’s Included:
HolsterInstalled 9 V batteryTest leadsUser manual
Fluke 114 Specifications
Accuracy Specifications
DC Millivolts
Range/resolution: 600.0/0.1 mV
Accuracy: ±([% of reading] + [counts]): 0.5% + 2
DC Volts
Range/resolution: 6.000 V/0.001, 60.00 V/0.01, 600.00/0.1 V
Accuracy: ±([% of reading] + [counts]): 0.5% + 2
Auto Volts
Range/resolution: 600.0/0.1 V
Accuracy: 2.0% + 3 (DC, 45 to 500 Hz), 4.0% + 3 (500 Hz to 1 kHz)
AC Millivolts True RMS
Range/resolution: 600.0/0.1 mV
Accuracy: 1.0% + 3 (DC, 45 to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
AC Volts True RMS
Range/resolution: 6.000 V/0.001, 60.00 V/0.01, 600.0/0.1 V
Accuracy: 1.0% + 3 (DC, 45 to 500 Hz), 2.0% + 3 (500 Hz to 1 kHz)
Continuity
Range/resolution: 600/1 Ω
Accuracy: Beeper on <20 Ω, off >250 Ω detects opens or shorts of 500 µs or longer.
Ohms
Range/resolution: 600.0/0.1 Ω, 6.000/0.001 kΩ, 60.00/0.01 kΩ, 600.0/0.1 kΩ, 6.000/0.001 MΩ
Accuracy: 0.9% + 1
Range/resolution: 40.00/0.01 MΩ
Accuracy: 5% + 2
General Specifications
Maximum Voltage Between Any Terminal and Earth Ground
600 V
Surge Protection
6 kV peak per IEC 61010-1 600 VCAT III, Pollution Degree 2
Display
Digital: 6000 counts, updates 4 per second
Bar Graph
33 segments, updates 32 per second
Operating Temperature
14 to 122°F (-10 to 50°C)
Storage Temperature
-40 to 140°F (-40 to 60°C)
Battery Type
9 V alkaline, NEDA 1604A/IEC 6LR61
Battery Life
400 hours typical, without backlight
Dimensions
6.57 x 3.31 x 1.82″ (167 x 84 x 46 mm)
Weight
1.2 lbs (550 g)
Click here for complete specifications on the Fluke 114
What’s included with the Fluke 114
Multimeter
Test Leads
Holster
9 V Battery (Installed)
User’s Manual
Reviews
There are no reviews yet.