Description

Confidently take reliable readings with the Fluke 355 AC/DC True-rms Clamp Meter – the tool of choice for high-current clamp-on amp meter measurements up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications and the extra rugged design has an extra element of user protection when taking high-powered measurements.

Industrial plants and large facilities often have equipment and installations that draw greater than 1000 A. As with other current measurements, it is not practical to disconnect the equipment to make a series of current measurements. The ability to check that an expensive system has been installed correctly, troubleshoot large loads, and make accurate measurements on UPS and Variable Frequency drives with noisy loads is also essential. In industrial settings, compliance with NFPA 70E safety standards, while making measurements, is critical. Fluke has addressed this by designing this product to meet CAT IV 600 V and CAT III 1000 V ratings.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. Additionally, the Fluke 355 measures voltage to 1000 V DC and 600 V AC (True-rms) and resistance to 400 k ohms with a continuity beeper, allowing utility technicians, electrical contractors and industrial service technicians to perform multiple tests with only one tool.

Applications:

Utilities (low-voltage vaults)
Industrial plants and facilities
Building maintenance, e.g. universities, hospitals, large offices, correctional institutions
Plant works, e.g. power, pharmaceutical, printing, automotive assembly
Manufacturing and process facilities
Refineries
Steel mills and other metal manufacturing plants
Large DC systems such as DC electroplating, or marine electrical systemsConfidently take reliable readings with the Fluke 355 AC/DC True-rms Clamp Meter – the tool of choice for high-current clamp-on amp meter measurements up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications and the extra rugged design has an extra element of user protection when taking high-powered measurements.

Industrial plants and large facilities often have equipment and installations that draw greater than 1000 A. As with other current measurements, it is not practical to disconnect the equipment to make a series of current measurements. The ability to check that an expensive system has been installed correctly, troubleshoot large loads, and make accurate measurements on UPS and Variable Frequency drives with noisy loads is also essential. In industrial settings, compliance with NFPA 70E safety standards, while making measurements, is critical. Fluke has addressed this by designing this product to meet CAT IV 600 V and CAT III 1000 V ratings.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. Additionally, the Fluke 355 measures voltage to 1000 V DC and 600 V AC (True-rms) and resistance to 400 k ohms with a continuity beeper, allowing utility technicians, electrical contractors and industrial service technicians to perform multiple tests with only one tool.

Applications:

Utilities (low-voltage vaults)
Industrial plants and facilities
Building maintenance, e.g. universities, hospitals, large offices, correctional institutions
Plant works, e.g. power, pharmaceutical, printing, automotive assembly
Manufacturing and process facilities
Refineries
Steel mills and other metal manufacturing plants
Large DC systems such as DC electroplating, or marine electrical systems

Fluke 355 Specifications

Current Measurement DC and AC 10 to 100 Hz

Range
40 A/400 A/2000 A/1400 AC RMS

Resolution
10 mA/100 mA/1 A

Accuracy
A: 1.5% rdg + 15 digits

A: 1.5% rdg + 5 digits

Trigger Level for Inrush
0.50 A/5.0 A/5 A

Trigger Level for Hz Filter OFF
2.50 A/2.5 A/8 A

Trigger Level for Hz Filter ON
0.50 A/2.5 A/8 A

Crest Factor (50/60 Hz)

Range
40 A/400 A/2000 A/1400 AC RMS

Crest Factor
2 at 33 A, 2.4 at 27 A

2 at 330 A, 2.4 at 270 A

2 at 1000 A, 2.4 at 833 A

Current Measurement AC 100.1 Hz to 1 kHz

Range
40 A/400 A/2000 A; 1400 AC RMS

Resolution
10 mA/100 mA/1 A

Accuracy
10 A: 3.5% rdg + 15 digits

10 A: 3.5% rdg + 5 digits

Trigger Level for Inrush
0.50 A/5.0 A/5 A

Trigger Level for Hz Filter OFF
2.50 A/2.5 A/8 A

Trigger Level for Hz Filter ON
0.50 A/2.5 A/8 A

Voltage Measurement DC and AC 10 to 100 Hz (600 and 1000 V ranges have 10% over range to 660 and 1100 V respectively)

Range
4 V/40 V/400 V/600 V AC RMS/1000 VDC

Resolution
1 mV/10 mV/100 mV/1 V

Accuracy
1% rdg + 10 digits

1% rdg + 5 digits

Trigger Level for Hz Filter OFF
0.25 V/6 V

Trigger Level for Hz Filter ON
0.25 V/6 V

Voltage measurement AC 100.1 Hz to 1 kHz (600 and 1000 V ranges have 10% over range to 660 and 1100 V respectively)

Range
4 V/40 V/400 V/600 V AC RMS/1000 VDC

Resolution
1 mV/10 mV/100 mV/1 V

Accuracy
3% rdg + 10 digits

3% rdg + 5 digits

Trigger Level for Hz Filter OFF
0.050 V/0.25 V/6 V

Trigger Level for Hz Filter ON
0.050 V/0.25 V /6 V

Ohms Measurement

Range
4 kΩ/40 kΩ/400 kΩ

Resolution
0.1 Ω/ 1 Ω/ 10 Ω/ 100 Ω

Accuracy
1.5% + 5 digits

Continuity Beeper

On and Off
On at ≤ 30 Ω

Off at > 100 Ω

Frequency Measurement

Measurement Range
5.0 Hz to 1 kHz

Resolution
0.1 Hz (15 Hz to 399.9 Hz)

1 Hz (400 Hz to 1 kHz)

Accuracy
5.0 to 100 Hz: 0.2% + 2 counts

100.1 Hz to 1 kHz: 0.5% + 5 counts

Environmental Specifications

Operating Temperature
32 to 122°F (0 to 50°C)

Storage Temperature
-4 to 140°F (-20 to 60°C)

Operating Humidity
0 to 95% (non-condensing)

Operating Altitude
6561.68′ (2000 m)

Storage Altitude
32,808.4′ (10,000 m)

IP Rating
42 (indoor use only)

Drop Test Requirements
3.28′ (1 m)

EMI, RFI, EMC
FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3V/m, performance criteria B, EN61325

Temperature Coefficients
Current: 0.1% of reading per °C outside 22 to 24°C

Voltage: 0.1% of reading per °C outside 22 to 24°C

General Specifications

Battery
Type: 6 x 1.5 V AA NEDA 15 A or IEC LR6

Life: 100 hours

Test Leads
Rated to 1000 V

Jaw Size
2.28″ (58 mm)

Dimensions
12 x 3.75 x 2″ (300 x 98 x 52 mm)

Weight
1.8 lbs (0.814 kg)

Safety Rating
IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

Click here for complete specifications on the Fluke 355

What’s included with the Fluke 355
Clamp Meter
4.9′ (1.5 m) Silicone Rubber Test Leads
Test Probes
Alligator Clips
Carrying Case
6 x AA Batteries
Users Manual
3-Year Warranty

Reviews

There are no reviews yet.

Be the first to review “Fluke 355 True RMS Clamp Meter, 2000 A”

Your email address will not be published. Required fields are marked *

Select your currency