HomeShopTesting EquipmentFluke 6109A-156 Portable Calibration Bath, 35 to 250°C

Description

Fluke 6109A-156 OffersHere is a portable calibration bath designed with the process manufacturing professional in mind. Process manufacturing plants for pharmaceuticals, biotechnology, and food production utilize many sanitary temperature sensors that require regular calibration. It is a liquid bath that lets process industry professionals calibrate four times more sanitary sensors per batch in less time and twice the accuracy of other portable baths.

Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ±0.1°C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. With these features, this calibration bath is ideal for professionals working in clean process industries, including facilities managers, production engineers, and calibration technicians.

Features

Calibrate up to four tri-clamp sanitary sensors at the same time
Wide temperature ranges cover most process applications
Excellent display accuracy of ±0.1°C provides 4:1 test uncertainty ratio (TUR) for critical applications
Easy to transport up stairs and across catwalks
Stainless steel casing withstands harsh sterilizing chemicals and is rust proof
Easy to use and maintain

Calibrate more sanitary sensors at a time – with confidence
Calibrates most temperature sensor applications used in clean process manufacturing, including pharmaceutical bioreactors (-10 to 100°C), chemical reactors (200°C), steam-in-place process (122 to 140°C), autoclave sterilization (120 to 135°C), and food processing (0 to 220°C).

A large tank volume (4.4 x 6.1″ [112 x 154 mm]) lets you immerse up to four sanitary sensors at the same time. Calibrate a batch of odd shaped temperature sensors of varying lengths and diameters, and still have room for a reference thermometer. Fast heating and cooling times let you get the job done without spending a lot of time waiting for the bath to come to temperature and stabilize. Increase your sanitary sensor calibration throughput and decrease expensive production downtime.

Excellent system display accuracy of ±0.1°C. Accuracy covers all sources of error including calibration uncertainty, stability, uniformity, and repeatability. NVLAP accredited calibration is included standard.

Take it almost anywhere, including the clean room
Features a fixed, non-rotating bail handle, enabling most people to carry a bath with one hand. Single-handed carrying comes in handy when the job includes walking up and down stairs, across catwalks, and into other hard-to-reach environments. Two recessed handles on the bottom of each bath also make it easy to move from a shelf to a cart or bench top. A sealed lid protects against fluid spills while moving the bath.

Stainless steel casing stands up to the harsh chemicals used to sterilize equipment for clean room use. Synthetic materials used for decals, keypads and feet do not harbor bacteria. The keypad is sealed against moisture ingress to protect against damage during cleaning or in non-controlled environments.

Easy to use and maintain
Features a large color display that indicates date and time, bath fluid temperature, set-point temperature, control indicator when the fluid is at set-point, and heating status. A ready indicator changes color from amber to green, giving you 360-degree visual indication when the bath fluid has reached its set-point temperature and is ready for you to start making measurements.

A hot warning indicator lights up if the fluid temperature reaches above 60°C, warning the operator that the bath fluid and tank area are hot and should not be touched. An adjustable probe fixture holds up to four tri-clamp sensors securely inside the tank opening during calibration.

Applications

Process manufacturing
Pharmaceutical
Biotechnology
Food production
Clean process industries
Facilities management
Production engineering
CalibrationFluke 6109A-156 OffersHere is a portable calibration bath designed with the process manufacturing professional in mind. Process manufacturing plants for pharmaceuticals, biotechnology, and food production utilize many sanitary temperature sensors that require regular calibration. It is a liquid bath that lets process industry professionals calibrate four times more sanitary sensors per batch in less time and twice the accuracy of other portable baths.

Larger than micro baths, up to four tri-clamp sanitary sensors fit easily into these baths for calibration at ±0.1°C temperature display accuracy. Throughput is even higher for sanitary RTDs with small or no flanges. With these features, this calibration bath is ideal for professionals working in clean process industries, including facilities managers, production engineers, and calibration technicians.

Features

Calibrate up to four tri-clamp sanitary sensors at the same time
Wide temperature ranges cover most process applications
Excellent display accuracy of ±0.1°C provides 4:1 test uncertainty ratio (TUR) for critical applications
Easy to transport up stairs and across catwalks
Stainless steel casing withstands harsh sterilizing chemicals and is rust proof
Easy to use and maintain

Calibrate more sanitary sensors at a time – with confidence
Calibrates most temperature sensor applications used in clean process manufacturing, including pharmaceutical bioreactors (-10 to 100°C), chemical reactors (200°C), steam-in-place process (122 to 140°C), autoclave sterilization (120 to 135°C), and food processing (0 to 220°C).

A large tank volume (4.4 x 6.1″ [112 x 154 mm]) lets you immerse up to four sanitary sensors at the same time. Calibrate a batch of odd shaped temperature sensors of varying lengths and diameters, and still have room for a reference thermometer. Fast heating and cooling times let you get the job done without spending a lot of time waiting for the bath to come to temperature and stabilize. Increase your sanitary sensor calibration throughput and decrease expensive production downtime.

Excellent system display accuracy of ±0.1°C. Accuracy covers all sources of error including calibration uncertainty, stability, uniformity, and repeatability. NVLAP accredited calibration is included standard.

Take it almost anywhere, including the clean room
Features a fixed, non-rotating bail handle, enabling most people to carry a bath with one hand. Single-handed carrying comes in handy when the job includes walking up and down stairs, across catwalks, and into other hard-to-reach environments. Two recessed handles on the bottom of each bath also make it easy to move from a shelf to a cart or bench top. A sealed lid protects against fluid spills while moving the bath.

Stainless steel casing stands up to the harsh chemicals used to sterilize equipment for clean room use. Synthetic materials used for decals, keypads and feet do not harbor bacteria. The keypad is sealed against moisture ingress to protect against damage during cleaning or in non-controlled environments.

Easy to use and maintain
Features a large color display that indicates date and time, bath fluid temperature, set-point temperature, control indicator when the fluid is at set-point, and heating status. A ready indicator changes color from amber to green, giving you 360-degree visual indication when the bath fluid has reached its set-point temperature and is ready for you to start making measurements.

A hot warning indicator lights up if the fluid temperature reaches above 60°C, warning the operator that the bath fluid and tank area are hot and should not be touched. An adjustable probe fixture holds up to four tri-clamp sensors securely inside the tank opening during calibration.

Applications

Process manufacturing
Pharmaceutical
Biotechnology
Food production
Clean process industries
Facilities management
Production engineering
Calibration

Fluke 6109A-156 Specifications

Range

(At 25°C Ambient Temperature)
35 to 250°C

Accuracy

(Maximum Permissible Error)
0.1°C

Display Resolution
0.01°, 0.001°

Stability
0.015°C

Uniformity (Typical)
0.03°C up to 200°C

0.04°C above 200°C

Repeatability
0.04°C

Heating Time (Typical)
35 to 100°C: 25 minutes

100 to 250°C: 45 minutes

Cooling Time (Typical)
250 to 100°C: 35 minutes

100 to 35°C: 55 minutes

Setting Time (Typical)
15 minutes

Fluid Volume
0.66 gal (2.5 L)

Fluid Working Area
3 x 3″ (75 x 75 mm)

Maximum Fluid Depth
6.1″ (154 mm)

Dimensions
15 x 9.5 x 15.7″ (382 x 242 x 400 mm)

Weight
35 lbs (16 kg)

Click here for complete specifications on the Fluke 6109A-156

What’s included with the Fluke 6109A-156
Calibration Bath
Report of Calibration with Label
Mains Power Cord
USB Cable
Probe Access Cover
Transport Tank Cover
Printed Safety Information
Product CD (Includes: Operator’s Manual, USB Driver, Software Distribution Licenses, Source Code for Public-Domain Software)