Fluke 83V OffersFeatures
Large digit display with bright, two-level backlight
Resistance, continuity and diode test
Min/Max-Average recording with Min/Max Alert to capture variations automatically
Relative mode to remove test lead interference from low ohms measurements
Auto and manual ranging for maximum flexibility
Touch hold to capture stable readings avoiding noisy signals
Large display digits and two-level bright white backlight for increased visibility
Analog bar graph for fast changing or unstable signals
Input alert provides audible warning against wrong use of input jacks
Improved selectable sleep mode for long battery life
Access door for fast battery changes without breaking the calibration seal
“Classic” design with new removable holster with built in test lead and probe storage
Electrical safety
All inputs are updated to the 3rd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Identify complex signal problems fast
When productivity is on the line and you need to solve problems fast, this multimeter delivers the accuracy and advanced troubleshooting capabilities you need.
Min/Max allows capture of signal changes
6000 count display resolution
CAT III 1000 V, CAT IV 600 V safety ratedFluke 83V OffersFeatures
Large digit display with bright, two-level backlight
Resistance, continuity and diode test
Min/Max-Average recording with Min/Max Alert to capture variations automatically
Relative mode to remove test lead interference from low ohms measurements
Auto and manual ranging for maximum flexibility
Touch hold to capture stable readings avoiding noisy signals
Large display digits and two-level bright white backlight for increased visibility
Analog bar graph for fast changing or unstable signals
Input alert provides audible warning against wrong use of input jacks
Improved selectable sleep mode for long battery life
Access door for fast battery changes without breaking the calibration seal
“Classic” design with new removable holster with built in test lead and probe storage
Electrical safety
All inputs are updated to the 3rd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.
Identify complex signal problems fast
When productivity is on the line and you need to solve problems fast, this multimeter delivers the accuracy and advanced troubleshooting capabilities you need.
Min/Max allows capture of signal changes
6000 count display resolution
CAT III 1000 V, CAT IV 600 V safety rated
Fluke 83V Specifications
Voltage DC
Maximum Voltage
1000 V
Accuracy
±(0.1% + 1)
Maximum Resolution
100 µV
Voltage AC
Maximum Voltage
1000 V
Accuracy
±(0.5% + 2)
Maximum Resolution
0.1 mV
Current DC
Maximum Amps
10 A (20 A for 30 seconds maximum)
Amps Accuracy
±(0.4% + 2)
Maximum Resolution
0.01 mA
Current AC
Maximum Amps
10 A (20 A for 30 seconds maximum)
Amps Accuracy
±(1.2% + 2)
Maximum Resolution
0.1 µA
Resistance
Maximum Resistance
50 MΩ
Accuracy
±(0.4% + 1)
Maximum Resolution
0.1 Ω
Capacitance
Maximum Capacitance
9999 µF
Accuracy
±(1% + 2)
Maximum Resolution
0.01 nF
Frequency
Maximum Frequency
200 kHz
Accuracy
±(0.005% + 1)
Maximum Resolution
0.01 Hz
Duty Cycle
Maximum Duty Cycle
99.9%
Accuracy
±(0.2% per khz + 0.1%)
Maximum Resolution
0.1%
Conductance
Maximum Conductance
60.00 nS
Accuracy
±(1.0% + 10)
Maximum Resolution
0.01 nS
Diode
Range
3 V
Resolution
1 mV
Accuracy
±(2% + 1)
Duty Cycle Range
Accuracy
Within ±(0.2% per kHz + 0.1%)
Environmental Specifications
Operating Temperature
-4 to 131°F (–20 to 55°C)
Storage Temperature
-40 to 140°F (–40 to 60°C)
Humidity (Without Condensation)
0 to 90% between 32 to 95°F (0 to 35°C)
0 to 70% between 95 to 131°F (35 to 55°C)
Operating Altitude
6561.68′ (2000 m)
Mechanical and General Specifications
Display
Digital: 6000 counts updates 4/sec
Analog: 32 segments, updates 40/sec
Frequency: 19,999 counts, updates 3/sec at > 10 Hz
Battery Life
Alkaline battery around 400 hours typical, without backlight
Shock
3.3′ (1 m) drop per IEC 61010–1:2001
Vibration
Per MIL–PRF–28800 for a Class 2 instrument
Dimensions
7.9 x 3.9 x 2″ (201 x 98 x 52 mm)
Weight
0.78 lbs (355 g)
Safety Specifications
Over Voltage Category
EN 61010–1 to 1000 V CAT III, 600V CAT IV
Agency Approvals
CSA, TÜV
Click here for complete specifications on the Fluke 83V
What’s included with the Fluke 83V
Multimeter
Test Leads
Alligator Clips
Holster
9 V Battery (Installed)
Lifetime Warranty
Reviews