Description

Fluke 9142-A-156 Low Temp Field Metrology Well Offers

Features

Auto setup requires the entry of only the nominal switch temperature, and with this entry it will run a 3-cycle calibration procedure and provide final results for the dead band temperature via the display
Manual setup allows you to program and run the procedure exactly how you would like
Each device (process and non-process versions) comes with an IEC-17025 NVLAP-accredited calibration certificate
Each calibration is backed with a 4:1 test uncertainty ratio
Display accuracy of ± 0.2°C over their full range
Stable to ± 0.01°C over its full range and the mid-range
Thermal block characteristics provide radial (well-to-well) uniformity performance to ±0.01°C
Dual-zone control helps these tools achieve axial uniformity to ±0.05°C at 40 mm (1.6″)

Applications
Ideal for the following applications: Laboratory, Education, R&D, Calibration Labs, Field Calibration, Industrial ProcessFluke 9142-A-156 Low Temp Field Metrology Well Offers

Features

Auto setup requires the entry of only the nominal switch temperature, and with this entry it will run a 3-cycle calibration procedure and provide final results for the dead band temperature via the display
Manual setup allows you to program and run the procedure exactly how you would like
Each device (process and non-process versions) comes with an IEC-17025 NVLAP-accredited calibration certificate
Each calibration is backed with a 4:1 test uncertainty ratio
Display accuracy of ± 0.2°C over their full range
Stable to ± 0.01°C over its full range and the mid-range
Thermal block characteristics provide radial (well-to-well) uniformity performance to ±0.01°C
Dual-zone control helps these tools achieve axial uniformity to ±0.05°C at 40 mm (1.6″)

Applications
Ideal for the following applications: Laboratory, Education, R&D, Calibration Labs, Field Calibration, Industrial Process

Fluke 9142-A-156 Specifications

Temperature Range
-25 to 150°C (-13 to 302°F)

Accuracy
±0.2°C (full range)

Stability
±0.01°C (full range)

Radial Uniformity
±0.01°C (full range)

Axial Uniformity @ 40mm (1.6″)
±0.05°C (full range)

Hysteresis
0.025

Heating Time
23 minutes

Cooling Time
15 mins to -25°C

Immersion Depth
150mm (6″)

Insert O.D.
30mm (1.18″)

Click here for complete specifications on the Fluke 9142-A-156

What’s included with the Fluke 9142-A-156
Fluke 9142-A-156 Low Temp Field Metrology Well