Description

Designed by electricians. Engineered by Fluke.

The Fluke 116 HVAC Multimeter features temperature and microamps measurements useful for heating, ventilation, air conditioning and refrigeration (HVAC/R) technicians. The Fluke 116 is a compact true-rms meter and has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.

The Fluke 116 also, has dual impedance capability: incorporating both regular high impedance test capabilities and low impedance functions for detecting ghost voltages, just switch to the Auto-V/LoZ (low impedance) test setting to whether measurement is a ghost voltage.

Auto-V stands for automatic volts. This feature automatically determines whether the measured signal is ac voltage or dc voltage, selects the correct function and range, and displays the correct information.LoZ stands for Low Impedance (Z). This feature presents a low impedance input to the circuit under test. This reduces the possibility of false readings due to ghost voltages and improves accuracy when testing to determine absence or presence of voltage.

Also check out the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.

What’s Included

4 mm silicone test lead set80BK Integrated Temperature probeHolsterInstalled 9 V batteryUser manualDesigned by electricians. Engineered by Fluke.

The Fluke 116 HVAC Multimeter features temperature and microamps measurements useful for heating, ventilation, air conditioning and refrigeration (HVAC/R) technicians. The Fluke 116 is a compact true-rms meter and has everything needed in an HVAC meter including temperature and microamp measurements to quickly troubleshoot problems with HVAC equipment and flame sensors.

The Fluke 116 also, has dual impedance capability: incorporating both regular high impedance test capabilities and low impedance functions for detecting ghost voltages, just switch to the Auto-V/LoZ (low impedance) test setting to whether measurement is a ghost voltage.

Auto-V stands for automatic volts. This feature automatically determines whether the measured signal is ac voltage or dc voltage, selects the correct function and range, and displays the correct information.LoZ stands for Low Impedance (Z). This feature presents a low impedance input to the circuit under test. This reduces the possibility of false readings due to ghost voltages and improves accuracy when testing to determine absence or presence of voltage.

Also check out the Fluke 114 Electrical Multimeter, the Fluke 115 Multimeter, and the Fluke 117, the Electrician’s Multimeter with Non-contact voltage.

What’s Included

4 mm silicone test lead set80BK Integrated Temperature probeHolsterInstalled 9 V batteryUser manual

Fluke 116 Specifications

Accuracy Specifications

DC Millivolts
Range: 600.0 mV

Resolution: 0.1 mV

Accuracy: 0.5 % + 2

DC Volts
Range: 6, 60, 600 V

Resolution: 0.001, 0.01, 0.1 V

Accuracy: 0.5 % + 2

Auto Volts
Range: 600.0 V

Resolution: 0.1 V

Accuracy: 2.0 % + 3 (dc, 45 to 500 Hz)

4.0 % + 3 (500 Hz to 1 kHz)

AC millivolts True RMS
Range: 600.0 mV

Resolution: 0.1 V

Accuracy: 1.0 % + 3 (dc, 45 to 500 Hz)

2.0 % + 3 (500 Hz to 1 kHz)

AC Volts True RMS
Range: 6, 60, 600 V

Resolution: 0.001, 0.01, 0.1 V

Accuracy: 1.0 % + 3 (dc, 45 to 500 Hz)

2.0 % + 3 (500 Hz to 1 kHz)

Continuity
Range: 600 Ω

Resolution: 1 Ω

Accuracy: Beeper on <20 Ω off> 250 Ω; detects opens or shorts of 500 µs or longer

Ohms
Range: 600 Ω, 6, 60, 600 kΩ, 6, 40 MΩ

Resolution: 1 Ω, 0.001, 0.01, 0.1 kΩ, 0.001, 0.01 MΩ

Accuracy: 0.9 % + 1

Diode Test
Range: 2.000 V

Resolution: 0.001 V

Accuracy: 0.9 % + 2

Capacitance
Range: 1000, nF, 10, 100, 9999, 100 to 1000, >1000 µF

Resolution: 1 nF, 0.01, 0.1, 1 µF

Accuracy: 0.9 % + 2, 1.9 % + 2, 5 % + 20

Lo-Z Capacitance
Range: 1 nF to 500µF

Accuracy: 10 % + 2 typical

Temperature (Type-K Thermocouple)
Range: -40 to 752 °F (-40 to 400 °C)

Resolution: 0.2 °F (0.1°C)

Accuracy: 1 % + 18

AC µAmps True RMS (45 to 500 Hz)
Range: 600.0 µA

Resolution: 0.1 µA

Accuracy: 1.5 % + 3 (2.5 % + 3 >500 Hz

DC µAmps
Range: 600.0 µA

Resolution: 0.1 µA

Accuracy: 1.0 % + 2

Hz (V or A input)
Range: 99.99, 999.9 Hz, 9.999, 50.00 kHz

Resolution: 0.01, 0.1 Hz, 0.001, 0.01 kHz

Accuracy: 0.1 % + 2

General Specifications

Maximum Voltage Between any Terminal and Earth Ground
600 V

Display
Digital: 6,000 counts, updates 4/sec

Bar Graph
33 segments, updates 32/sec

Operating Temperature
14 to 122°F (-10 to 50°C)

Storage Temperature
-40 to 140°F (-40 to 60°C)

Battery
9 V Alkaline, NEDA 1604A/IEC 6LR61

Battery Life
400 hours typical, without backlight

Surge Protection
6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2

Click here for complete specifications on the Fluke 116

What’s included with the Fluke 116
Multimeter
Test Leads
Integrated Temperature Probe
Yellow Rubber Boot
Battery (Installed)
User Manual

Reviews