Description
Fluke 1732/B OffersThree-phase power measurements made easy
Deliver easy to use three-phase power measurement data for locating sources of electrical energy waste, overloaded circuits and help users do routine load studies. Find out when and where energy in your facility is being used – from the service entrance to individual circuits. This electrical energy logger is Fluke Connect compatible which allows users to access and share three-phase power data remotely with their team so they can maintain safer working distances and make critical decisions in real-time, minimizing the need for protective equipment, site visits, and check-ins.
Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.
Features
Key measurements: automatically capture and log voltage, current, power, power factor, energy and associated values
Fluke Connect® compatible: view data locally on the instrument, via Fluke Connect mobile app and desktop software or through your facilities’ WiFi infrastructure
Convenient instrument powering: power instrument directly from the measured circuit
Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream
Measure all three phases
Comprehensive logging: more than 20 separate logging sessions can be stored on the instruments
Optimized user interface: quick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty
Bright, color touch screen: perform convenient in-the-field analysis and data checks with full graphical display
Optimized user interface: capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function
Complete “in-the-field” setup through the front panel or Fluke Connect: no need to return to the workshop for download and setup or to take a computer to the electrical panel
Energy Analyze Plus application software: download and analyze every detail of energy consumption with our automated reporting
Applications
Energy studies – full range of electrical power and energy parameters
Load studies – simple current only logging for load sizing
General facilities staff
Facilities engineers
Building managers concerned with energy costs
Residential/commercial electricians
Energy consultantsFluke 1732/B OffersThree-phase power measurements made easy
Deliver easy to use three-phase power measurement data for locating sources of electrical energy waste, overloaded circuits and help users do routine load studies. Find out when and where energy in your facility is being used – from the service entrance to individual circuits. This electrical energy logger is Fluke Connect compatible which allows users to access and share three-phase power data remotely with their team so they can maintain safer working distances and make critical decisions in real-time, minimizing the need for protective equipment, site visits, and check-ins.
Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.
Features
Key measurements: automatically capture and log voltage, current, power, power factor, energy and associated values
Fluke Connect® compatible: view data locally on the instrument, via Fluke Connect mobile app and desktop software or through your facilities’ WiFi infrastructure
Convenient instrument powering: power instrument directly from the measured circuit
Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance and downstream
Measure all three phases
Comprehensive logging: more than 20 separate logging sessions can be stored on the instruments
Optimized user interface: quick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty
Bright, color touch screen: perform convenient in-the-field analysis and data checks with full graphical display
Optimized user interface: capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function
Complete “in-the-field” setup through the front panel or Fluke Connect: no need to return to the workshop for download and setup or to take a computer to the electrical panel
Energy Analyze Plus application software: download and analyze every detail of energy consumption with our automated reporting
Applications
Energy studies – full range of electrical power and energy parameters
Load studies – simple current only logging for load sizing
General facilities staff
Facilities engineers
Building managers concerned with energy costs
Residential/commercial electricians
Energy consultants
How Can The Fluke 1732 and 1734 Work For You
Load Studies
Discover how much energy
individual pieces of equipment are consuming
when they are operating at minimum and
maximum capacity. Check capacity of circuits
prior to adding additional loads (various
standards exist for this process; in the US the NEC 220-87 is the recommended standard). Load studies can also identify situations where you may be exceeding the allowable load on the circuit or
when an agreed peak demand applies from the
utility. For convenience, some load studies simply
measure current which makes installation of the
measuring equipment quick and easy. It is often
recommended that load surveys be performed
for 30 days so that all typical load conditions are
encountered during the test.
Logging Related Analog Measurements
When conducting energy studies, it is useful to log
related analog measurements such as
temperature,voltage, current or pressure. These variables provide a better overall picture of operating conditions and allow you to correlate asset
performance data with energy consumption.
Correlating these variables provides more of the
data you need to make cost saving performance
adjustments. With the Fluke 1734, up to two
Fluke Connect wireless modules can be used to
capture these measurements, and the values will
be automatically logged along with power and
energy readings.
Simplified Load Studies
For situations where it’s either difficult or impractical to make a voltage connection the simple load study feature allows users to perform a simplified load study by measuring current only. The user can enter the nominal expected voltage to create a simulated power study. For accurate power and energy studies it is required to monitor both voltage and current but this simplified method is useful in certain circumstances.
Use up to two Fluke Connect wireless modules with the Fluke 1734 to capture analog measurements.
Energy Assessments
Quantify energy consumption before, and after
improvements, to justify energy saving devices.
Energy Surveys
Users often ask where measurements
should be taken for an energy survey. The
answer is multiple points within the facility. Start
at the main service feeders; compare the power
and energy measured here with the readings
from the utility meter to ensure you’re receiving
the correct charges. Then move downstream to
the larger loads; these should be easy to identify
by the current rating of the electrical panels
downstream of the service entrances. Measuring
at many points will allow a full picture of energy
usage across the facility to be developed. The
next question users typically have is how long an
energy survey should last. This of course depends
on the facility, but it is recommended that you
measure for a period that matches a typical facility
activity period. If the facility operates over
a five day work week with down time on the
weekend, a seven day survey will most likely
capture typical conditions. If the facility operates at a constant level for 24 hours a day, 365 days a
year, a single day could be reasonably representative as long as you avoid a period where there
may be planned maintenance. To capture a full picture of the facilities energyusage it is not necessarily required to have measurements made simultaneously at every consumption point in the facility. To get a comprehensive picture, spot measurements can be made and then compared on a sliding time timescale.For example, you could compare the service entrance results from a typical Tuesday between 6:00 am and 12:00 pm with those of a larger load in the facility. Typically there will be some correlation between these profiles.
Power and Energy Logging
When a piece of
equipment is operated it instantaneously consumes a specific amount of power in watts (W) or
kilowatts (kW). This power is accumulated over
the operating time and expressed as energy consumed in kilowatt hours (kWh). Energy is what
your electric utility charges for; there will be a
standard charge from the utility per kilowatt hour.
Utilities may have other additional charges, such
as peak demand, which is the maximum power
demand over a defined period of time, often 15 or
30 minutes.
There may also be power factor charges, which
are based on the effects of the inductive or
capacitive loads in the facility. Optimizing peak
demand and power factor often results in lower
monthly electricity bills. The 1733 and Fluke
1734 Three Phase Electrical Energy loggers have
the capability to measure and characterize these
effects enabling you to analyze the results and
save money.
Fluke 1732/B Specifications
Voltage
Range
1000 V
Resolution
0.1 V
Intrinsic Accuracy at Reference Conditions
(% of Reading +% of Full Scale)
±(0.2% + 0.01%)
Frequency
Range
42.5 to 69 Hz
Resolution
0.01 Hz
Intrinsic Accuracy at Reference Conditions
(% of Reading +% of Full Scale)
±(0.1%)
Auxillary Input
Range
±10 V dc
Resolution
0.1 mV
Intrinsic Accuracy at Reference Conditions
(% of Reading +% of Full Scale)
±(0.2% + 0.02%)
Voltage Min/Max
Range
1000 V
Resolution
0.1 V
Intrinsic Accuracy at Reference Conditions
(% of Reading +% of Full Scale)
±(1% + 0.1%)
Current Min/Max
Range
Defined by accessory
Resolution
Defined by accessory
Intrinsic Accuracy at Reference Conditions
(% of Reading +% of Full Scale)
±(5% + 0.2%)
THD on Voltage
Range
1000%
Resolution
0.1%
Intrinsic Accuracy at Reference Conditions
(% of Reading +% of Full Scale)
±0.5
THD on Current
Range
1000%
Resolution
0.1%
Intrinsic Accuracy at Reference Conditions
(% of Reading +% of Full Scale)
±0.5
Power Supply
Voltage Range
100 to 500 V using safety plug input when powering from the measurement circuit
100 to 240 V using standard power cord (IEC 60320 C7)
Power Consumption
Maximum 50 VA (max. 15 VA when powered using IEC 60320 input)
Efficiency
≥68.2% (in accordance with energy efficiency regulations)
Maximum No-Load Consumption
≤0.3 W only when powered using IEC 60320 input
Mains Power Frequency
50/60 Hz ±15%
Battery
Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-Battery Runtime
Four hours in standard operating mode, up to 5.5 hours in power saving mode
Charging Time
<6 hours
Data Acquisition
Resolution
16-bit synchronous sampling
Sampling Frequency
10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input Signal Frequency
50/60 Hz (42.5 to 69 Hz)
Circuit Types
1-φ, 1-φ IT, Split phase, 3-φ delta, 3-φ wye, 3-φ wye IT
3-φ wye balanced, 3-φ Aron/Blondel (2-element delta)
3-φ delta open leg, Currents only (load studies)
Data Storage
Internal flash memory (not user replaceable)
Memory Size
Typical 10 logging sessions of 8 weeks with 1-minute intervals and 500 events
Basic Interval
Measured Parameters
Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Averaging Interval
User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging Time Min/Max Values
Voltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200ms
Demand Interval (Energy Meter Mode)
Measured Parameters
Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Interval
User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Standards Compliance
Power
IEEE 1459
Interfaces
USB-A
File transfer via USB flash drive, firmware updates max. current: 120 mA
WiFi
File transfer and remote control via direct connection or WiFi infrastructure
Bluetooth
Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 upgrade option)
USB-Mini
Data download device to PC
Voltage Inputs
Number of Inputs
4 (3 phases and neutral)
Maximum Input Voltage
1000 Vrms, CF 1.7
Input Impedance
10 MΩ
Bandwidth (-3 dB)
42.5 Hz to 3.5 kHz
Scaling
1:1 and variable
Measurement Category
1000 V CAT III/600 V CAT IV
Current Inputs
Number of Inputs
3, mode selected automatically for attached sensor
Input Voltage
Clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski Coil Input
150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe range
Range
1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12"
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24"
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36"
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
Bandwidth (-3 dB)
42.5 Hz to 3.5 kHz
Scaling
1:1 and variable
Auxiliary Inputs
Number of Inputs
2
Input Range
0 to ±10 V dc, 1reading/s
Scale Factor
Format: mx + b (gain and offset) user configurable
Displayed Units
User configurable (7 characters, for example, °C, psi, or m/s)
Wireless Connection
Number of Inputs
2
Supported Modules
Fluke Connect® 3000 series
Acquisition
1 reading/s
Environmental Specifications
Operating Temperature
14 to 122 °F (-10 to 50°C)
Storage Temperature
-4 to 140°F (-20 to 60°C)
With battery: -4 to 122 °F (-20 to 50°C)
Operating Humidity
50 to 86°F (10 to 30°C) max. 95% RH
86 to 104°F (30 to 40°C) max. 75% RH
104 to 122°F (40 to 50 °C) max. 45% RH
Operating Altitude
6561.7' (2000 m) [up to 13,123.4' (4000 m) derate to 1000 V CAT II/600 V CAT III/300 V CAT IV]
Storage Altitude
39,370' (12,000 m)
Enclosure
IP50 in accordance with EN60529
Vibration
MIL-T-28800E, Type 3, Class III, Style B
Safety
IEC 61010-1
IEC Mains Input: Overvoltage Category II, Pollution Degree 2
Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
IEC 61010-2-031: CAT IV 600 V / CAT III 1000 V
Electromagnetic Compatibility
EN 61326-1: Industrial CISPR 11: Group 1, Class A
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
Temperature Coefficient
0.1 x accuracy specification/°C
General Specifications
Color LCD Display
4.3" (109 mm) active matrix TFT, 480 pixels x 272 pixels, resistive touch panel
Dimensions
Instrument: 7.8 x 6.6 x 2.2" (198 x 167 x 55 mm)
Power supply: 5.1 x 5.1 x 1.8" (130 x 130 x 45 mm)
Instrument with power supply attached: 7.8 x 6.6 x 3.5" (198 x 167 x 0.9 mm)
Weight
Instrument: 2.5 lbs (1.1 kg)
Power supply: 0.9 lb (400 g)
Click here for complete specifications on the Fluke 1732/B
What's included with the Fluke 1732/B
Energy Logger
Voltage Test Leads
4 x Alligator Clips
Line Cords
Carrying Case
Power Supply
Color Coding Set
See it. Save it. Share it. All the facts, right in the field.
Fluke engineers have delivered an innovative mobile platform and tool that helps solve everyday problems, allowing you to instantly document measurements, retrieve historical data, and share live measurements with your team. All handled by the Android™ or iOS smart phone you already carry.
Fluke Connect with ShareLive™ video call is the only wireless measurement system that lets you stay in contact with your entire team without leaving the field. The Fluke Connect mobile app is works with over 20 different Fluke products - the largest suite of connected test tools in the world.
Make the best decisions faster than ever before by viewing temperature, mechanical, electrical and vibration measurements for each equipment asset in one place. Get started saving time and increasing your productivity.
Fluke Connect Features:
TrendIt™ Graphs: Use graphing to show changes in measurements, allowing you to graph and show problems instantly.
EquipmentLog™ History: Access equipment history building a database of equipment health and baselines with cloud backup.
ShareLive™ Video Calls: Save, collaborate and share measurements instantly with your team anytime, from anywhere.
AutoRecord™ Measurements: Instantly save measurements to your phone with Cloud backup.
Fluke Cloud™ Storage: Securely access equipment records anywhere, anytime.
Fluke Connect Benefits:
Maximize uptime
Minimize maintenance costs
Better assessments with accurate records
Higher efficiency with less walking around; no notebook and excel needed
Share troubleshooting knowledge live
Create and share helpful content in the field
Access to Fluke digital product manuals means no need to carry manuals in the field
Keep organized manually entered measurements
Webinar: Electrical Power Testing
It’s no secret that power quality can have a big impact on productivity and safety in the workplace. That’s why there’s been a rapid increase in the demand for electrical power measurement equipment recently. With that in mind, having an effective frontline troubleshooting and reliability tactic should be a priority. Keeping track of the power quality in your facility plays an important part in avoiding costs related to poor power quality management like productivity costs, reduced efficiency, higher energy bills, and capital equipment degradation and failure.
Webinar: Introduction to Portable Precision Power Analyzers with Fluke
This wideband precision analyzer is accurate enough for the lab, yet it's built for the field. Offering you more freedom than ever before to make high accuracy power measurements wherever you need to. Whether in the lab or in the field. Designed for portability and eliminates the need to carry large, fragile, expensive analyzers into the field, allowing you to make measurements directly at the load in nearly any environment. By measuring directly at the load, you can discover how the equipment operates under real-world conditions, with real-world variables, not just at a test bench or in the lab.
Reviews
There are no reviews yet.