Description
Fluke 9009-B-156 Offers
Eliminating the need to wait for multiple temperature points during calibration, this unique dual unit allows you to calibrate your sensor in the heated well while the cool well stabilizes. By having two independently controlled temperature blocks, one for heating and one for cooling, with a combined range of 5 to 662°F (-15 to 350°C), the time saved is well worth it.
Features
Two independently controlled temperature blocks, one for heating and one for cooling with a combined range of -15 to 350°C
Unique dual unit allows you to calibrate your sensor in the heated well while the cool well stabilizes; this eliminates the need to wait for multiple temperature points during calibration
Each block is controlled by a precision Hart Scientific temperature controller
Inserts are available to accommodate sensors of any size from 1/16″ (1.6 mm) to 7/16″ (11.1 mm)
RS-232 connection and Interface-it software allows you to control and monitor temperatures from your PC
For completely automated calibrations, Hart’s MET/TEMP II software also integrates with the 9009
A single AC connection powers both temperature wells for convenience at the job site
Housed in a tough Pelican™ case that is both airtight and watertight
Both wells accept the same removable inserts so that you only have to keep one set on hand for both wells (four inserts are stored in the wells, and an additional four can be stored in a convenient holding rack inside the case)
Applications
Laboratory
Education
R&D
Lab calibration
Field calibrationFluke 9009-B-156 Offers
Eliminating the need to wait for multiple temperature points during calibration, this unique dual unit allows you to calibrate your sensor in the heated well while the cool well stabilizes. By having two independently controlled temperature blocks, one for heating and one for cooling, with a combined range of 5 to 662°F (-15 to 350°C), the time saved is well worth it.
Features
Two independently controlled temperature blocks, one for heating and one for cooling with a combined range of -15 to 350°C
Unique dual unit allows you to calibrate your sensor in the heated well while the cool well stabilizes; this eliminates the need to wait for multiple temperature points during calibration
Each block is controlled by a precision Hart Scientific temperature controller
Inserts are available to accommodate sensors of any size from 1/16″ (1.6 mm) to 7/16″ (11.1 mm)
RS-232 connection and Interface-it software allows you to control and monitor temperatures from your PC
For completely automated calibrations, Hart’s MET/TEMP II software also integrates with the 9009
A single AC connection powers both temperature wells for convenience at the job site
Housed in a tough Pelican™ case that is both airtight and watertight
Both wells accept the same removable inserts so that you only have to keep one set on hand for both wells (four inserts are stored in the wells, and an additional four can be stored in a convenient holding rack inside the case)
Applications
Laboratory
Education
R&D
Lab calibration
Field calibration
Fluke 9009-B-156 Specifications
Range
Hot block: 122 to 662°F (50 to 350°C)
Cold block: 5 to 230°F (–15 to 110°C) (17 to 230°F (-8 to 110°C) when hot block is at 662°F (350°C))
Accuracy (Ambient at 23°C ±5°C)
Hot block: ±0.6°C
Cold block: ±0.2°C
Stability
Hot block: “0.1°C from 122 to 212°F (50 to 100°C), “0.05°C > 212°F (100°C)
Cold block: °0.05°C
Well-to-Well Uniformity
±0.1°C
Display Resolution
0.1°
Heating Times
Hot block: 30 minutes from 77 to 662°F (25 to 350°C)
Cold block: 15 minutes from 77 to 230°F (25 to 110°C)
Cooling Times
Hot block: 40 minutes from 662 to 212°F (350 to 100°C)
Cold block: 16 minutes from 77 to 5°F (25 to -15°C)
Stabilization Times
8 minutes
Well Depth
4″ (102 mm)
Removable Inserts
Two ¼” (6.4 mm) and 3/16″ (4.8 mm) inserts included
Power
115 VAC (±10%), 50/60 Hz, 3 A, 250 W
Heater
Hot block: 135 W
Cold block: 40 W TED
Cooling
Hot block: Fan
Cold block: 40 W TED
Dimensions
7 x 10.5 x 9.75″ (178 x 267 x 248 mm)
Weight
10 lbs (4.5 kg)
Safety
Over Voltage (Installation) CATEGORY II, Pollution Degree 2 per IEC1010-1
Click here for complete specifications on the Fluke 9009-B-156
What’s included with the Fluke 9009-B-156
Dry Well
Report of Calibration with Calibration Label
2 x 3102-3 ( 3/16″) and two 3102-4 (¼”) Inserts
Power Cord
RS-232 Cable
Insert Removal Tool
User’s Manual
Webinar: Temperature Calibrations with Fluke
We understand the importance of the performance of temperature and pressure instruments in your business as often being critical when trying to optimize operations, product quality or to ensure proper functioning of safety systems. As such, we’ve teamed up with Fluke to offer you a series of two webinars on this topic. The first will provide valuable information to help you identify temperature calibration improvements in your business. The second will focus on identifying pressure calibration improvements.
Let’s start with Temperature Calibrations… This valuable one-hour Fluke seminar will give you the knowledge to quickly identify improvements to your temperature calibrations and associated workflows. Providing you with key insights when reviewing your temperature calibration workload and highlights the latest “best practices”, methods and tools that will allow you to maximize results when testing the most common temperature instruments.
During this 1-hour webinar, we’ve covered:
• Temperature calibration – an overview and review
• Workload and applications checklist
• Identify, isolate and eliminate common sources of error
• Best practices and tech tips
• Using technology for workflow improvements
• How to maximize your results