Description
Fluke 754/FPC Offers
Providing reliable results, this documenting process calibrator monitors, controls, calibrates HART instrumentation, records, and stores results. Simultaneously source and measure capabilities and communicate via industry-standard digital protocols.
Features
Multifunctional: Calibrate temperature, pressure, voltage, current, resistance, and frequency; since it both measures and sources, troubleshoot and calibrate all with one rugged tool
Powerful, yet easy to use: The easy-to-follow, menu-driven display guides you through any task, and programmable calibration routines enable you to create and run automated as-found/as-left procedures to ensure fast, consistent, calibrations
Records and documents results: To support ISO-9000 or regulatory standards, it captures calibration results, eliminating the need to juggle a pen and pad in the field, and the USB interface lets you transfer the results to a PC
Connect to calibration management software
Handles fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms
Measures/sources pressure using any of 29 Fluke 700Pxx Pressure Modules
Creates and runs automated as-found/as-left procedures to satisfy quality programs or regulations, and records and documents results
Holds up to a full week of downloaded procedures and calibration results
Uses many features like autostep, custom units, user-entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more
Provides easy-to-use multi-lingual interface that displays instructions in English, French, German, Spanish, and Italian
Features a bright white dual display for reading both sourced and measured parameters simultaneously
Truly hand-held: Small enough to fit easily into a tool bag and to use in tight spaces, and runs an entire shift on a rechargeable Li-ion battery pack
Rugged and reliable: Overmolded urethane case stands up to rough handling in industrial environments
Bright white display lets you read results in any kind of light, and the backlight has three settings
Soft keys provide one-touch access to enhanced functions such as task lists, automated procedures, scaling, minimum/maximum, stepping and ramping, and review memory
Three operating modes: Measure, Source, or simultaneous Measure/Source enables technicians to troubleshoot, calibrate, or maintain instrumentation with just one tool
Integrated HART communication capability lets you program and control HART instrumentation
Use it immediately without a learning curve
AutoStep allows technicians to set the calibrator for a delayed start and a specific sequence of steps, so it can run unattended as a continuously varying test source
User entered values enable users to capture readings measured or sourced by other devices
Custom units allow readings to be scaled and displayed in any user-defined units
Switch calibration procedures perform fast, automated calibration of one- and two-point switches for voltage, current, temperature, and pressure
Differential pressure flow instrument calibration routines use a square root function to directly calibrate DP flow instruments
Built-in algebraic calculator with four functions – plus square root – stores, recalls, and performs calculations required for setting up instruments or evaluating data in the field; use it to set the source function to a calculated value
Programmable measurement delay inside automated procedures permits calibrating instruments that respond slowly
Work smarter and faster
Whether you’re calibrating instruments, troubleshooting a problem, or running routine maintenance, this documentating process calibrator with HART communication can help you get the job done faster. It does so many different tasks, so quickly and so well, it’s the only process calibrator you need to carry. This rugged, reliable integrated communicating calibrator is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.
This unit is a power multifunction documenting calibrator that you can use to download procedures, lists, and instructions created with software; or upload data for printing, archiving, and analysis. The powerful built-in HART interface is capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.
In fact, this calibrator does the work of several tools. It sources, simulates and measures pressure, temperature, and electrical signals with one rugged, hand-held device. For documentation, it automates calibration procedures and captures your data, and, of course, helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. Plus, the graphical screen, Li-Ion battery for longer life, USB port, and accessories help you work smarter and faster.
Applications
Calibration
Maintenance
Troubleshooting
Application Selection Guide
Model number
754
721/721Ex
719Pro
719
718
717
700G
3130
2700G
Dead-weight Testers
Application
Calibrating pressure transmitters (field)
●
●
Ideal
●
●
●
●
Calibrating pressure transmitters (bench)
●
●
●
●
●
●
Ideal
●
Calibrating HART Smart transmitters
Ideal
Documenting pressure transmitter calibrations
Ideal
Testing pressure switches in the field
Ideal
●
●
●
●
●
●
Testing pressure switches on the bench
●
●
●
●
●
●
Ideal
Documenting pressure switch tests
Ideal
Testing pressure switches with live (voltage) contacts
Ideal
Gas custody transfer computer tests
●
Ideal
●
Verifying process pressure gauges (field)
Ideal
●
●
●
●
●
●
Verifying process pressure gauges (bench)
●
●
●
●
●
●
●
●
Ideal
Logging pressure measurements
●
Ideal
●
Testing pressure devices using a reference gauge
Ideal
Hydrostatic vessel testing
Ideal
Leak testing (pressure measurement logging)
●
Ideal
Pressure Calibration Selection Guide
Includes Fluke Premium Care Support – One-Year Plan
Reduce unplanned expenses and get the most out of your tools
When you invest in quality equipment to get your jobs done, you want your money to go as far as possible.
Fluke Premium Care provides coverage above and beyond your tool’s original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair. It’s easy too! You’ll receive your product with the information and register. That’s it, you’re covered!Fluke 754/FPC Offers
Providing reliable results, this documenting process calibrator monitors, controls, calibrates HART instrumentation, records, and stores results. Simultaneously source and measure capabilities and communicate via industry-standard digital protocols.
Features
Multifunctional: Calibrate temperature, pressure, voltage, current, resistance, and frequency; since it both measures and sources, troubleshoot and calibrate all with one rugged tool
Powerful, yet easy to use: The easy-to-follow, menu-driven display guides you through any task, and programmable calibration routines enable you to create and run automated as-found/as-left procedures to ensure fast, consistent, calibrations
Records and documents results: To support ISO-9000 or regulatory standards, it captures calibration results, eliminating the need to juggle a pen and pad in the field, and the USB interface lets you transfer the results to a PC
Connect to calibration management software
Handles fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms
Measures/sources pressure using any of 29 Fluke 700Pxx Pressure Modules
Creates and runs automated as-found/as-left procedures to satisfy quality programs or regulations, and records and documents results
Holds up to a full week of downloaded procedures and calibration results
Uses many features like autostep, custom units, user-entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay and more
Provides easy-to-use multi-lingual interface that displays instructions in English, French, German, Spanish, and Italian
Features a bright white dual display for reading both sourced and measured parameters simultaneously
Truly hand-held: Small enough to fit easily into a tool bag and to use in tight spaces, and runs an entire shift on a rechargeable Li-ion battery pack
Rugged and reliable: Overmolded urethane case stands up to rough handling in industrial environments
Bright white display lets you read results in any kind of light, and the backlight has three settings
Soft keys provide one-touch access to enhanced functions such as task lists, automated procedures, scaling, minimum/maximum, stepping and ramping, and review memory
Three operating modes: Measure, Source, or simultaneous Measure/Source enables technicians to troubleshoot, calibrate, or maintain instrumentation with just one tool
Integrated HART communication capability lets you program and control HART instrumentation
Use it immediately without a learning curve
AutoStep allows technicians to set the calibrator for a delayed start and a specific sequence of steps, so it can run unattended as a continuously varying test source
User entered values enable users to capture readings measured or sourced by other devices
Custom units allow readings to be scaled and displayed in any user-defined units
Switch calibration procedures perform fast, automated calibration of one- and two-point switches for voltage, current, temperature, and pressure
Differential pressure flow instrument calibration routines use a square root function to directly calibrate DP flow instruments
Built-in algebraic calculator with four functions – plus square root – stores, recalls, and performs calculations required for setting up instruments or evaluating data in the field; use it to set the source function to a calculated value
Programmable measurement delay inside automated procedures permits calibrating instruments that respond slowly
Work smarter and faster
Whether you’re calibrating instruments, troubleshooting a problem, or running routine maintenance, this documentating process calibrator with HART communication can help you get the job done faster. It does so many different tasks, so quickly and so well, it’s the only process calibrator you need to carry. This rugged, reliable integrated communicating calibrator is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.
This unit is a power multifunction documenting calibrator that you can use to download procedures, lists, and instructions created with software; or upload data for printing, archiving, and analysis. The powerful built-in HART interface is capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.
In fact, this calibrator does the work of several tools. It sources, simulates and measures pressure, temperature, and electrical signals with one rugged, hand-held device. For documentation, it automates calibration procedures and captures your data, and, of course, helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. Plus, the graphical screen, Li-Ion battery for longer life, USB port, and accessories help you work smarter and faster.
Applications
Calibration
Maintenance
Troubleshooting
Application Selection Guide
Model number
754
721/721Ex
719Pro
719
718
717
700G
3130
2700G
Dead-weight Testers
Application
Calibrating pressure transmitters (field)
●
●
Ideal
●
●
●
●
Calibrating pressure transmitters (bench)
●
●
●
●
●
●
Ideal
●
Calibrating HART Smart transmitters
Ideal
Documenting pressure transmitter calibrations
Ideal
Testing pressure switches in the field
Ideal
●
●
●
●
●
●
Testing pressure switches on the bench
●
●
●
●
●
●
Ideal
Documenting pressure switch tests
Ideal
Testing pressure switches with live (voltage) contacts
Ideal
Gas custody transfer computer tests
●
Ideal
●
Verifying process pressure gauges (field)
Ideal
●
●
●
●
●
●
Verifying process pressure gauges (bench)
●
●
●
●
●
●
●
●
Ideal
Logging pressure measurements
●
Ideal
●
Testing pressure devices using a reference gauge
Ideal
Hydrostatic vessel testing
Ideal
Leak testing (pressure measurement logging)
●
Ideal
Pressure Calibration Selection Guide
Includes Fluke Premium Care Support – One-Year Plan
Reduce unplanned expenses and get the most out of your tools
When you invest in quality equipment to get your jobs done, you want your money to go as far as possible.
Fluke Premium Care provides coverage above and beyond your tool’s original product warranty, so you don’t need to worry about unexpected downtime caused by damaged test equipment, accessories, or tools in need of calibration or repair. It’s easy too! You’ll receive your product with the information and register. That’s it, you’re covered!
Fluke 754/FPC Specifications
Measurement Accuracy
Voltage DC
Range/resolution: 100 mV, 3, 30, 300 V
1 year: 0.02% + 0.005 mV, 0.02% + 0.00005, 0.02% + 0.0005, 0.05% + 0.05 V
2 years: 0.03% + 0.005 mV, 0.03% + 0.00005, 0.03% + 0.0005, 0.07% + 0.05 V
Voltage AC
Range/resolution: 3 V (40 to 500 Hz)/0.001 V
1 year: 0.5% + 0.002, 0.5% + 0.02, 0.5% + 0.2 V
2 years: 1% + 0.004, 1% + 0.04, 1% + 0.2 V
Resistance
Range/resolution: 10, 100, Ω, 1, 10 kΩ
1 year: 0.05% + 50, 0.05% + 50, 0.05% + 500 mΩ, 0.1% + 10 Ω
2 years: 0.07% + 70, 0.07% + 70 mΩ, 0.07% + 0.5, 0.15% + 15 Ω
Frequency
Range/resolution: 1 to 110/0.01, 110.1 to 1100 Hz/0.1 Hz, 1.101 to 11/0.001, 11.01 to 50 kHz/0.01 kHz
2 years: 0.05, 0.5 Hz, 0.0005, 0.05 kHz
Source Accuracy
Voltage DC
Range/resolution: 100 mV, 1, 15 V
1 year: 0.01% + 0.005 mV, 0.01% + 0.00005, 0.01% + 0.0005 V
2 years: 0.015% + 0.005 mV, 0.015% + 0.0005, 0.015% + 0.0005 V
Current DC
Range/resolution: 22.000 mA (source), Current sink (simulate)
1 year: 0.01% + 0.003, 0.02% + 0.007 mA
2 years: 0.02% + 0.003, 0.04% + 0.007 mA
Resistance
Range/Resolution: 10, 100 Ω, 1, 10 kΩ
1 year: 0.01% + 10, 0.01% + 20 mΩ, 0.02% + 0.2, 0.02% + 3 Ω
2 years: 0.015% + 15, 0.015% + 30 mΩ, 0.03% + 0.3, 0.03% + 5 Ω
Frequency
Range/resolution: 0.1 to 10.99, 0.01 to 10.99, 11.00 to 109.99, 110.0 to 1099.9 Hz, 1.100 to 21.999, 22.000 to 50 kHz
2 years: 0.01, 0.01, 0.1, 0.1 Hz, 0.002, 0.005 kHz
General Specifications
Environmental Conditions
Operating temperature: 14 to 122°F (-10 to 50°C)
Storage temperature: -20 to 140°F (-20 to 60°C)
Dust/water resistance: Meets IP52, IEC 529
Operating altitude: 9842′ (3000 m) above mean sea level
Agency Approvals
CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
Data Storage Capacity
One week of calibration procedures results
Battery
Type: Internal battery pack Li-ion (7.2 V, 4400 mAh, 30 Wh)
Life: >8 hours typical
Dimensions
5.4 x 9.6 x 2.5″ (136 x 245 x 63 mm)
Weight
2.7 lbs (1.23 kg)
Click here for complete specifications on the Fluke 754/FPC
What is HART?
HART, the Highway Addressable Remote Transducer protocol, uses a 1200 baud Frequency Shift Keying (FSK) signal to superimpose digital information on the conventional 4 to 20 mA analog signal.
Why use the HART protocol?
HART is an industry standard developed to define the communications protocol between intelligent field devices and a control system, HART is the most widely used digital communication protocol in the process industry. More than five million HART field instruments are installed in more than 100,000 plants worldwide. The HART protocol:
Is supported by all of the major suppliers of process field instruments supported by the HART Communication Foundation, an industry-wide non-profit organization
Preserves present control strategies
Allows traditional 4 to 20 mA signals and digital communication to share the same two-wire loops
Provides important information for installation and maintenance: Tag IDs, measured values, range and span data, product information and diagnostics
Reduces operation costs by making it easier to manage and fully utilize “smart” instrument network
Fluke 754 HART Documenting Process Calibrator:
Get HART-ability
Process plants have taken advantage of smart transmitters, the need for a new generation of calibrators has emerged – calibrators that can communicate via industry standard digital protocols. This process calibrator combines HART communication capability in a documenting process calibrator to deliver an integrated communicating calibrator. This rugged, reliable tool is ideal for calibrating, maintaining, and troubleshooting HART instrumentation. This process calibrator offers:
Integrated HART communication functions, permitting you to monitor, control, and calibrate HART instrumentation
Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 mS
Li-ion battery with 4400 mA hour life and gas gauge
The field calibrator for HART instruments that’s both powerful and easy to use
This process calibrator offers the most complete HART implementation of any process calibrator. This process calibrator:
Requires no external box or second tool for everyday HART calibration and maintenance
Offers fast HART communication
Supports popular models of HART transmitters with device-specific command support
Fully complies with the Data Link Layer of the HART protocol, including multiple masters, burst mode,
and multi-drop configurations
Is easy to update as additional instruments are added and new HART versions are released
Is based on the 740 series calibrators, the most rugged, reliable multifunction field calibrators ever made
Is backed by the service and support of the Fluke organization, a member of the HART Communications Foundation
This process calibrator is designed to take on nearly all the day-to-day tasks you now perform with a separate communicator. In fact, it offers many of the communication capabilities of the 475 HART communicator except for the DD interpreter, which can read command set libraries from any HART supplier. This is not necessary for daily HART maintenance.
How to calibrate a HART smart pressure transmitter
Pressure transmitter manufacturers have improved the accuracy and technology designed into these smart pressure measurement devices. Many conventional calibration tools have become inadequate or simply unable to test and calibrate these high accuracy pressure transmitters. Better test solutions are required.
Verifying and documenting the performance and adjusting a HART smart pressure transmitter can require a bucket full of tools. Performing this task with a HART enabled calibrator like this process calibrator simplifies the task and reduces what you need to carry.
Before going to the field, install the pressure module adapter to the hand pump with thread seal. Once the adapter is properly installed on the pump, changing modules to different pressure ranges is a snap, no tools required.
To get the accuracy needed to test these new high accuracy transmitters, match the pressure measurement standard range closely to the device tested. For example, use a 100 psi pressure module to calibrate and test a transmitter ranged at 100 psi. Industry standards suggest the measurement standard should be 4 to 10 times more accurate than the device being tested, so best-in-class accuracy is required.
This Documenting Process Calibrator-HART utilizes the 750P series pressure module and has the HART functionality built in to enable smart trims on transmitters. It can also document transmitter performance before and after adjustment and calculate pass/fail errors.
To perform the test:
Isolate the transmitter from the process being measure and its loop wiring. If measuring the mA signal across the transmitter test diode leave the wires intact, but note this method does not give the best mA measurement accuracy.
Connect the mA measurement jacks of this process calibrator to the transmitter.
Connect the pressure module cable to this process calibrator and connect the transmitter test hose from the hand pump to the transmitter.
Press the HART button on the calibrator to see the configuration of the transmitter.
Press HART again and the calibrator will offer the correct measure/source combination for the test. If documenting the calibration press As-Found, input the test tolerance and follow the prompts. If the measured mA signal at the test points is found within tolerance the test is complete. If not, adjustment is required.
Select, adjust, and trim the pressure zero, mA output signal and input sensor.
After adjustment select As-Left, document the condition of the transmitter and after adjustment and if the test passes, it is complete.
HART applications
Fluke 754: The HART calibrator that is easy to use.
Versatile HART protocol support
This process calibrator supports the commands contained in HART protocol version 5.7.
This process calibrator supports a substantial set of HART instructions:
Universal commands – provide functions that are implemented in all field devices, for example, read manufacturer and device type, read primary variable (PV), or read current output and percent of span
Common practice commands – provide functions that are common to many but not all field devices, for example read multiple variables, set damping time, or perform loop test
Device-specific commands – provide functions that are unique to a particular field device, for example sensor trim
Today’s 754 supports device-specific instructions for a variety of popular instruments. Additional support may be added periodically with a simple software update available on diskette or via download for a modest upgrade fee.
Manufacturer
Pressure Instruments
Temperature Instruments
Coriolis Instruments
ABB/Kent-Taylor
600T
658T1
ABB/Hartmann & Braun
Contrans P1, AS 800 Series
Endress & Hauser
CERABAR S, CERABAR M, DELTABAR S
TMT 1221, TMT 1821, TMT 1621
Foxboro Eckardt
TI/RTT201
Foxboro/Invensys
I/A Pressure
Fuji
FCX, FCXAZ
FRC
Honeywell
ST3000
STT25T1, STT25H1
Micro Motion
2000, 2000IS, 9701, 9712, 9739
Moore Products
3441
Rosemount
1151, 2088, 3001C, 3051, 3051S
3044C, 644, 3144, 3244, 3144P
Siemens
SITRANS P DS
SMAR
SITRANS P DS, SITRANS P ES
Viatran
LD301
TT3011
Wika
UNITRANS
Yokogawa
EJA
YTA 110, 310 and 320
1Sensor trim not supported
HART Operating Modes Supported
For Point to Point operation, the most commonly used mode, connects this process calibrator to a single HART device in a 4 to 20 mA loop.
In Multi-Drop mode, several HART instruments can be bussed together. This process calibrator searches for each, identifies addresses in use, and allows you to select the instrument for calibration and related operations.
In Burst Mode, the HART instrument transmits bursts of data without waiting to be interrogated by a master unit. This process calibrator can take transmitters out of burst mode during test or calibration, then later restore them to burst mode.
What’s included with the Fluke 754/FPC
Documenting Process Calibrator
NIST-Traceable Calibration Report and Data
USB Communication Cable
HART Communications Cable
3 x Sets of Test Probes with Three Sets of “Extended Tooth” Alligator Clips
2 x Sets of Hook Clip
Soft Field Carrying Case
Battery Charger
Li-Ion Battery Pack
Instruction Manual
DPCTrack 2 Sample Software
One-Year Premium Care Plan
Three-Year Warranty
Reviews