Description

Fluke 9102S-156 Dry Block Temperature Calibrator Offers

Features

For work in the temperature range of -10 to 122°C
Stable to ±0.05°C
Includes a NIST-traceable calibration
Excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient
Two wells so you can use one for a reference thermometer to increase accuracy.
Both wells are 1/2″ in diameter, and each has inserts available for almost any sensor size
Battery pack option that gives you approximately four hours of field use when AC power is unavailable
Removable insert sleeves 1/2″ O.D. x 4″ deep (13 mm x 102mm) and comes complete with 1/4″ and 3/16″ inserts (order additional insert sizes as needed)

Applications
Ideal for the following applications: Laboratory, Education, R&D, Calibration Labs, Field CalibrationFluke 9102S-156 Dry Block Temperature Calibrator Offers

Features

For work in the temperature range of -10 to 122°C
Stable to ±0.05°C
Includes a NIST-traceable calibration
Excellent for dial gauges, digital thermometers, bulb switches, and other sensors that need calibration below ambient
Two wells so you can use one for a reference thermometer to increase accuracy.
Both wells are 1/2″ in diameter, and each has inserts available for almost any sensor size
Battery pack option that gives you approximately four hours of field use when AC power is unavailable
Removable insert sleeves 1/2″ O.D. x 4″ deep (13 mm x 102mm) and comes complete with 1/4″ and 3/16″ inserts (order additional insert sizes as needed)

Applications
Ideal for the following applications: Laboratory, Education, R&D, Calibration Labs, Field Calibration

Fluke 9102S-156 Specifications

Temperature Range
-10 to 122°C (14 to 252°F) @ 23°C ambient

Accuracy
±0.25°C

Stability
±0.05°C

Well-to-Well Uniformity
±0.10°C @ 35°C, ±0.50°C @ 200°C, ±1.00°C @ 500°C

Well Depth
4″ (102mm)

Stabilization Time
7 minutes

Heating Time
Ambient to 100°C: 10 minutes

Cooling Time
Ambient to 0°C: 10 minutes

Click here for complete specifications on the Fluke 9102S-156

What’s included with the Fluke 9102S-156
Fluke 9102S-156 Dry Block Temperature Calibrator

Reviews

There are no reviews yet.

Be the first to review “Fluke 9102S-156 Dry Block Temperature Calibrator”

Your email address will not be published. Required fields are marked *

Select your currency