Description
Fluke 1623-2-KIT Offers
Simpler, faster earth ground tests than ever before. The tester has internal memory storage with up to 1500 records, accessible via USB port for rapid data transfer and viewing of results. It comes with world-class accessories. New wire reels, speed up setup and tear down time as much as 50%. Heavy duty stakes can be hammered into dry, hard soil. Set up is simpler with new color-coded wires that help eliminate mistakes.
Features
One-button measurement concept
3- and 4-pole earth ground measurement
4-pole soil resistivity testing
Selective testing, no disconnection of ground conductor (one clamp)
Stakeless testing, quick ground loop testing (two clamps)
Measuring frequency 128 Hz
Applications
Oil and gasMining/mineral and metal processingProcess manufacturing – chemical processingUtilitiesManufacturing: machinery, instrumentation, and appliancesFluke 1623-2-KIT Offers
Simpler, faster earth ground tests than ever before. The tester has internal memory storage with up to 1500 records, accessible via USB port for rapid data transfer and viewing of results. It comes with world-class accessories. New wire reels, speed up setup and tear down time as much as 50%. Heavy duty stakes can be hammered into dry, hard soil. Set up is simpler with new color-coded wires that help eliminate mistakes.
Features
One-button measurement concept
3- and 4-pole earth ground measurement
4-pole soil resistivity testing
Selective testing, no disconnection of ground conductor (one clamp)
Stakeless testing, quick ground loop testing (two clamps)
Measuring frequency 128 Hz
Applications
Oil and gasMining/mineral and metal processingProcess manufacturing – chemical processingUtilitiesManufacturing: machinery, instrumentation, and appliances
Specifications
Temperature Range
Operating Temperature
14 to 122°F (-10 to 50°C)
Storage Temperature
-22 to 140°F (-30 to 60°C)
Temperature Coefficient
±0.1% of reading/°C <18°C >28°C
Intrinsic Error
Refers to the reference temperature range and is guaranteed for one year
Operating Error
Refers to the operating temperature range and is guaranteed for one year
Climatic Class
C1 (IEC 654-1), 23 to 115°F (-5 to 45°C), 5 to 95% RH
Protective Type
IP56 for case, IP40 for battery door according to EN60529
Safety
Protection by double and/or reinforced insulation maximum 50 V to earth. IEC61010-1: 300V CAT II, Pollution degree two
EMC (Emission Immunity)
IEC61326-1: Portable
Quality System
Developed, designed, and manufactured according to DIN ISO 9001
External Voltage
V external, maximum = 24 V (dc, ac <400 Hz), measurement inhibited for higher values
V Ext Rejection
>120 dB (16²⁄3, 50, 60, 400 Hz)
Measuring Time
Typical six seconds
Maximum Overload
250 V rms (pertains to misuse)
Auxiliary Power
6 x 1.5 V Alkaline (type AA LR6)
Battery Life Span
Typical >3000 measurements
RA 3-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position
RA 3-pole
Resolution
0.001 to 10 Ω
Measuring Range
0.020 Ω to 19.99 kΩ
Accuracy
±(2% rdg + 3 d)
Operating Error
±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage
Vm = 48 V ac
Short-Circuit Current
>50 mA
Measure Frequency
128 Hz
Probe Resistance (RS)
Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH)
Maximum 100 kΩ
Additional Error from RH and RS
RH[kΩ]RS[kΩ]/RA[Ω]0.2%
RA 4-Pole Ground Resistance Measurement (IEC 1557-5)
Switch Position
RA 4-pole
Resolution
0.001 to 10 Ω
Measuring Range
0.020 Ω to 19.99 kΩ
Accuracy
±(2% rdg + 3 d)
Operating Error
±(5% rdg + 3 d)
Measuring Principle: Current/Voltage Measurement
Measuring Voltage
Vm = 48 V ac
Short-Circuit Current
>50 mA
Measure Frequency
128 Hz
Probe Resistance (RS + RES)
Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH)
Maximum 100 kΩ
Additional Error from RH and RS
RH[kΩ]RS[kΩ]/RA[Ω]0.2%
Monitoring of RS and RH with error indicator.
Automatic range selection.
RA 3-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position
RA 3-pole with clamp
Resolution
0.001 to 10 Ω
Measuring Range
0.020 Ω to 19.99 kΩ
Accuracy
±(7% rdg + 3 d)
Operating Error
±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage
Vm = 48 V ac
Short-Circuit Current
>50 mA
Measure Frequency
128 Hz
Probe Resistance (RS)
Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH)
Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
RA 4-Pole Selective Ground Resistance Measurement with Current Clamp (RA with Clamp)
Switch Position
RA 4-pole with clamp
Resolution
0.001 to 10 Ω
Measuring Range
0.020 Ω to 19.99 kΩ
Accuracy
±(7% rdg + 3 d)
Operating Error
±(10% rdg + 5 d)
Measuring Principle: Current/Voltage Measurement (with External Current Clamp)
Measuring Voltage
Vm = 48 V ac
Short-Circuit Current
>50 mA
Measure Frequency
128 Hz
Probe Resistance (RS)
Maximum 100 kΩ
Auxiliary Earth Electrode Resistance (RH)
Maximum 100 kΩ
Monitoring of RS and RH with error indicator.
Automatic range selection.
Measurement is not performed if the current through the current clamp is too low.
Stakeless Ground Loop Measurement (2 Clamps)
Switch Position
RA 4-pole 2 clamps
Resolution
0.001 to 10 Ω
Measuring Range
0.020 Ω to 19.99 kΩ
Accuracy
±(7% rdg + 3 d)
Operating Error
±(10% rdg + 5 d)
Measuring Principle: Stakeless Measurement of Resistance in Closed Loops Using Two Current Transformers
Measuring Voltage
Vm = 48 V ac
Measure Frequency
128 Hz
Noise Current (IEXT)
Maximum IEXT = 10 A (ac) (RA <20 Ω)
General Specifications
Display
1999 Digit LCD: Display with special symbols, digit height 25 mm, fluorescent backlight
User Interface
Instant measurement through TURN and START one button concept. The only operating elements are rotary switch and START button
Robust, Water and Dust Resistant
Instrument is designed for tough environmental conditions (rubber protective cover, IP56)
Memory
Internal memory storage up to 1500 records accessible via USB port
Dimensions
9.75 x 5.25 x 7.35" (250 x 133 x 187 mm)
Weight
2.43 lbs (1.1 kg) including batteries
16.8 lbs (7.6 kg) included accessories and batteries in carrying case
Click here for complete specifications on the Fluke 1623-2-KIT
What's included with the Fluke 1623-2-KIT
Fluke Tester
2 x Test Leads
4 x Earth Ground Stakes
3 x Cable Reels with Wire
2 x Clamps (One Inducing, One Sensing)
Batteries
Rugged Carrying Case
Users Manual