Description
New! Fluke 753
You’re going to love what we’ve done with your calibrator.
The Fluke 753 is everything you needed and wished for in the 743B and more!
The 753 does the work of several tools – sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graphical screen, Li-on battery for longer life, USB port and new accessories to complete the package.
For documentation, the 753 automates calibration procedures and captures your data.
And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.
Fluke 753 Features
Work smarter. Work faster.
The 753 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis.
Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
Power transmitters during test using loop supply with simultaneous mA measurement
Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
Holds up to a full week of downloaded procedures and calibration results.
Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
Easy to use
Three year warranty
Bright white dual display. Read both sourced and measured parameters simultaneously.
Multi lingual interface
Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge.
Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
Delivered with DPC/Track Sample software.
Compatible with many Asset Management software packages.New! Fluke 753
You’re going to love what we’ve done with your calibrator.
The Fluke 753 is everything you needed and wished for in the 743B and more!
The 753 does the work of several tools – sourcing, simulating and measuring pressure, temperature, and electrical signals in one rugged, hand-held device. You’ll fall in love with the new improved graphical screen, Li-on battery for longer life, USB port and new accessories to complete the package.
For documentation, the 753 automates calibration procedures and captures your data.
And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations.
Fluke 753 Features
Work smarter. Work faster.
The 753 is a power multifunction documenting calibrator that lets you download procedures, lists, and instructions created with software-or upload data for printing, archiving, and analysis.
Measure volts, mA, RTDs, thermocouples, frequency, and ohms to test sensors, transmitters and other instruments
Source/simulate volts, mA, thermocouples, RTDs, frequency, ohms, and pressure to calibrate transmitters
Power transmitters during test using loop supply with simultaneous mA measurement
Measure/source pressure using any of 29 Fluke 700Pxx Pressure Modules
Create and run automated as-found/as-left procedures to satisfy quality programs or regulations. Record and document results
Holds up to a full week of downloaded procedures and calibration results.
Use many features like autostep, custom units, user entered values during test, one-point and two-point switch testing, square root DP flow testing, programmable measurement delay etc.
Easy to use
Three year warranty
Bright white dual display. Read both sourced and measured parameters simultaneously.
Multi lingual interface
Rechargeable Li-Ion battery for 10 hour uninterrupted use. Includes gas gauge.
Handling of fast pulsed RTD transmitters and PLCs, with pulses as short as 1 ms.
Delivered with DPC/Track Sample software.
Compatible with many Asset Management software packages.
Fluke 753 Specifications
Measurement Accuracy
Voltage DC
Range/resolution: 100 mV, 3 V, 30 V, 300 V
1 year: 0.02% + 0.005 mV, 0.02% + 0.00005 V, 0.02% + 0.0005 V, 0.05% + 0.05 V
2 years: 0.03% + 0.005 mV, 0.03% + 0.00005 V, 0.03% + 0.0005 V, 0.07% + 0.05 V
Voltage AC
Range/resolution: 3 (40 to 500 Hz)/0.001 V, 30 (40 to 500 Hz)/0.01 V, 300 (40 to 500 Hz)/0.1 V
1 year: 0.5% + 0.002 V, 0.5% + 0.02 V, 0.5% + 0.2 V
2 years: 1.0% + 0.004 V, 1.0% + 0.04 V, 1.0% + 0.2 V
Current DC
Range/resolution: 30 mA, 110 mA
1 year: 0.01% + 5 µA, 0.01% + 20 µA
2 years: 0.015% + 7 µA, 0.015% + 30 µA
Resistance
Range/resolution: 10 Ω, 100 Ω, 1 kΩ, 10 kΩ
1 year: 0.05% + 50 mΩ, 0.05% + 50 mΩ, 0.05% + 500 mΩ, 0.1% + 10 Ω
2 years: 0.07% + 70 mΩ, 0.07% + 70 mΩ, 0.07% + 0.5 Ω, 0.15% + 15 Ω
Frequency
Range/resolution: 1.00 to 110.00 Hz/0.01 Hz, 110.1 to 1100.0 Hz/0.1 Hz, 1.101 to 11.000 kHz/0.001 kHz, 11.01 to 50.00 kHz/0.01 kHz
2 years: 0.05 Hz, 0.5 Hz, 0.005 kHz, 0.05 kHz
Source Accuracy
Voltage DC
Range/resolution: 100 mV, 1 V, 15 V
1 year: 0.01% + 0.005 mV, 0.01% + 0.00005 V, 0.01% + 0.0005 V
2 years: 0.015% + 0.005 mV, 0.015% + 0.0005 V, 0.015% + 0.0005 V
Current DC
Range/resolution: 22 mA (source), current sink (simulate)
1 year: 0.01% + 0.003 mA, 0.02% + 0.007 mA
2 years: 0.02% + 0.003 mA, 0.04% + 0.007 mA
Resistance
Range/resolution: 10 Ω, 100 Ω, 1 kΩ, 10 kΩ
1 year: 0.01% + 10 mΩ, 0.01% + 20 mΩ, 0.02% + 0.2 Ω, 0.02% + 3 Ω
2 years: 0.015% + 15 mΩ, 0.015% + 30 mΩ, 0.03% + 0.3 Ω, 0.03% + 5 Ω
Frequency
Range/resolution: 0.1 to 10.99 Hz, 0.01 to 10.99 Hz, 11.00 to 109.99 Hz, 110.0 to 1099.9 Hz, 1.100 to 21.999 kHz, 22.000 to 50.000 kHz
2 years: 0.01 Hz, 0.01 Hz, 0.1 Hz, 0.1 Hz, 0.002 kHz, 0.005 kHz
Technical Data
Data Log Functions
Measure functions: Voltage, current, resistance, frequency, temperature, pressure
Reading rate: 1, 2, 5, 10, 20, 30, or 60 readings/minute
Maximum record length: 8000 readings (7980 for 30 or 60 readings/minute)
Ramp Functions
Source functions: Voltage, current, resistance, frequency, temperature
Rate: 4 steps/second
Trip detect: Continuity or voltage (continuity detection not available when sourcing current)
Loop Power Function
Voltage: Selectable, 26 V
Accuracy: 10%, 18 V minimum at 22 mA
Maximum current: 25 mA, short circuit protected
Maximum input voltage: 50 V DC
Step Functions
Source functions: Voltage, current, resistance, frequency, temperature
Manual step: Selectable step, change with arrow buttons
Autostep: Fully programmable for function, start delay, step value, time per step, repeat
Environmental Specifications
Operating Temperature
14 to 122°F (-10 to 50°C)
Storage Temperature
-4 to 140°F (-20 to 60°C)
Dust/Water Resistance
Meets IP52, IEC 529
Operating Altitude
9842′ (3000 m) above mean sea level
Mechanical and General Specifications
Batteries
Internal battery pack Li-ion: 7.2 V, 4400 mAh, 30 Wh
Battery Life
>8 hours typical
Battery Replacement
Via snap-shut door without opening calibrator; no tools required
Side Port Connections
Pressure module connector
USB Connector to interface to your PC
Connection for optional battery charger/eliminator
Data Storage Capacity
1 week of calibration procedures results
90 Day Specifications
The standard specification interval are 1 and 2 years
Typical 90 day measurement and source accuracy can be estimated by dividing the one year “% of reading” or “% of output” specifications by 2.
Floor specifications, expressed as “% of full scale” or “counts” or “ohms” remain constant.
Dimensions
5.4 x 9.6 x 2.5″ (136 x 245 x 63 mm)
Weight
2.7 lbs (1.2 kg)
Safety Specifications
Agency Approvals
CAN/CSA C22.2 No 1010.1-92, ASNI/ISA S82.01-1994, UL3111, and EN610-1:1993
Click here for complete specifications on the Fluke 753
What’s included with the Fluke 753
Calibrator
NIST-Traceable Calibration Report and Data
USB Communication Cable
3 x Test Probes
3 x Sets of “Extended Tooth”” Alligator Clips
2 x Hook Clips
Carrying Case
Li-on Battery Pack
Battery Charger
DPCTrack 2™ Sample Software
Instruction Manual
Reviews